OpenAlex 541 works 42 author topics
Works
541 works
-
YÖKSİS
SJR Q1
JCR Q3
OpenAlex 85.1%
The requirements of an islanding, or 'loss of grid', protection for a dispersed storage and generation unit are examined, and the principal methods used for this type of relaying are outlined. A new protection algorithm is introduced which is based on the rate of change of power as measured at the generator's terminal…
-
OpenAlex 85.4%
Digital protection is based on the use of computers in power line relaying. Since the late 1960s, digital devices and techniques have been applied to almost all new protection schemes. Today the technology is moving towards standardised hardware platforms; at the software level, however, there remains a huge variety i…
-
YÖKSİS
SJR Q1
JCR Q1
OpenAlex top 1%
OpenAlex 99.2%
No abstract yet.
-
YÖKSİS
SJR Q1
JCR Q1
OpenAlex top 10%
OpenAlex 97.8%
Inverter-Based Resources (IBRs), including Wind turbine generators (WTGs), exhibit substantially different negative-sequence fault current characteristics compared to synchronous generators (SGs). These differences may cause misoperation of customary negative-sequence-based protective elements set under the assumption…
-
YÖKSİS
SJR Q1
JCR Q2
OpenAlex 87.0%
In recent years, there has been a growing interest in incorporating microgrids in electrical power networks. This is due to various advantages they present, particularly the possibility of working in either autonomous mode or grid connected, which makes them highly versatile structures for incorporating intermittent g…
-
YÖKSİS
SJR Q1
JCR Q4
OpenAlex 89.5%
No abstract yet.
-
A New Microprocessor Based Islanding Protection Algorithm for Dispersed Storage and Generation Units 1995YÖKSİS SJR Q1 JCR Q3 OpenAlex 14.2%
The ability to detect when dispersed storage and generation (DSG) units become islanded from the main source of generation enables the DSG to be quickly disconnected from the utility network and for that network to be rebuilt in a safe and orderly manner. The new islanding protection algorithm described in the paper h…
-
YÖKSİS
SJR Q1
JCR Q1
OpenAlex top 1%
OpenAlex 99.0%
No abstract yet.
-
YÖKSİS
SJR Q1
JCR Q3
OpenAlex top 10%
OpenAlex 98.3%
Inverter-based resources (IBRs) exhibit different short-circuit characteristics compared to traditional synchronous generators (SGs). Hence, increased uptake of IBRs in the power system is expected to impact the performance of traditional protective relay schemes—set under the assumption of a SG-dominated power system…
-
Fault Detection and Classification in Ring Power System With DG Penetration Using Hybrid CNN-LSTM 2024YÖKSİS SJR Q1 JCR Q2 OpenAlex top 1% OpenAlex 99.8%
A modern electric power system integrated with advanced technologies such as sensors and smart meters is referred to as a "smart grid," aimed at enhancing electrical power delivery efficiency and reliability. However, fault location and prediction can become challenging when dynamic fault currents from renewable energ…
-
YÖKSİS
SJR Q2
JCR Q2
OpenAlex top 10%
OpenAlex 97.6%
No abstract yet.
-
Power system protection with digital overcurrent relays: A review of non-standard characteristics 2018YÖKSİS SJR Q1 JCR Q2 OpenAlex top 10% OpenAlex 96.7%
No abstract yet.
Academicians
42 academicians
- ÖMER USTA 32 author topics
- EMRE ÖZKOP 20 author topics
- ŞERİFE SALMAN 20 author topics
- MEHMET HAKAN HOCAOĞLU 19 author topics
- MUSTAFA BAYSAL 14 author topics
- BAHADIR AKBAL 12 author topics
- ABDULFETAH ABDELA SHOBOLE 11 author topics
- MOHAMMED VADİ 11 author topics
- FATİH MEHMET NUROĞLU 9 author topics
- SERAP KARAGÖL YALÇIN 9 author topics
- YILMAZ ASLAN 8 author topics
- DÜZGÜN AKMAZ 7 author topics