Article detail · 2019 · article
Mineralization of olive mill wastewater under hydrothermal conditions
Data source split
- YÖKSİSYÖKSİS article record
- YÖKSİS venueDesalination and Water Treatment
- Catalog match (ISSN)Desalination and Water Treatment
- OpenAlexOpenAlex enrichment (abstract, citations, topics)
- Semantic Scholarcitation count (not merged with OpenAlex)
Abstract
ABSTRACT Olive mill wastewater (OMW) is highly dangerous for land and aquatic environments because of its high phenolic content, acidity, and salinity. Hence, hydrothermal degradation of OMW in subcritical water medium with and without using external oxidizer (H 2 O 2 ) was studied to decrease its total organic carbon (TOC), total phenolic content (TPC), and color. Effects of reaction temperature (150°C–250°C), reaction time (30–120 min), and H 2 O 2 content (0–100 mM) on TOC and TPC of OMW were investigated. Box-Behnken-type experimental design and statistical analysis (analysis of variance) were practiced by Design Expert 11. According to statistical analysis, effect of reaction temperature significantly affected TOC removal efficiency. The best TOC reduction (31.65%) was achieved without using H 2 O 2 at 250°C for 120 min.
Topics
Citations
OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.
1citationsOpenAlex · cited_by_count (cache / database)