Skip to content
akaturk Academic measurement
Search

Article detail · 2024 · article

Response surface methodology use in construction of polianiline‐coated carbon paste electrode–based biosensor: Modification and characterization

YÖKSİS OpenAlex Open access · bronze
Year2024
Citations4OpenAlex
Percentile%51.6
FWCI0.331.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueBiotechnology and Applied Biochemistry
  • Catalog match (ISSN)Biotechnology and Applied Biochemistry
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

Abstract In this study, the effect of amperometric glucose biosensor construction and using conditions on the current response was investigated in detail applying experimental design. Polyaniline (PANI) was synthesized on the carbon paste electrode (CPE) surface using the cyclic voltammetry technique in sodium oxalate (NaOx) electrolyte medium, and an amperometric biosensor was constructed by immobilizing glucose oxidase (GOD). Biosensor preparation (aniline, GOD and NaOx concentrations, and scan rate) and operating conditions (pH and applied potential) were optimized by Box–Behnken and optimal designs, respectively, via State Ease Design Expert 7.0.1.1 software. ANOVA analyses showed that among the biosensor preparation parameters, the NaOx concentration has the highest effect on the current measured in the presence of glucose, whereas in the optimization of pH and potential parameters applied in current measurement studies, it has been revealed that pH has a very high effect on the measured current. Several compounds, such as MWCNT, two different ionic liquids and two different organic molecules were added to carbon paste, and, among them, 2‐cyanoethylpyrrole (CPy) enhanced the efficacy highly, most probably due to its polymerization in the paste and increasing the electron transfer rate of the CPE. Sucrose‐ and lactose‐sensitive biosensors were also constructed by co‐immobilizing GOD with invertase (INV) or β‐galactosidase, respectively, onto modified CPE, and sensitivities to their substrates were shown by cyclic voltammetry and impedance analysis. CPy modification caused an increase in the current values, and also Imax/KM values increased approximately 11.8, 7.83, and 2.56 times for glucose‐, sucrose‐, and lactose‐sensitive CPEs, respectively.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

4citationsOpenAlex · cited_by_count (cache / database)

3 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).

  1. 2023 Glucose-Sensitive Biosensor Design by Zinc Ferrite (ZnFe2O4) Nanoparticle-Modified Poly (o-toluidine) FilmCitations 16 · OpenAlex
  2. 2025 Comparative Study of Metal Oxide Nanoparticles for Enhanced Amperometric Glucose Detection in Real Samples Using a Polypyrrole-Based BiosensorCitations 0 · OpenAlex
  3. 2025 Application of RSM to optimize protein parameters in pineapple and kiwi juicesCitations 0 · OpenAlex

Authors

3
  1. Esra Yağız 1
  2. GÜL ÖZYILMAZ 2
  3. ALİ TUNCAY ÖZYILMAZ HATAY MUSTAFA KEMAL ÜNİVERSİTESİ 3