Article detail · 2020 · article
Manganese sensitised-indirect determination of melamine in milk-based samples by flame atomic absorption spectrometry coupled with ultrasound assisted-cloud point extraction
Data source split
- YÖKSİSYÖKSİS article record
- YÖKSİS venueInternational Journal of Environmental Analytical Chemistry
- Catalog match (ISSN)International Journal of Environmental Analytical Chemistry
- OpenAlexOpenAlex enrichment (abstract, citations, topics)
- Semantic Scholarcitation count (not merged with OpenAlex)
Abstract
In the current study, a simple and low- cost method of UA-CPE in combination with flame atomic absorption spectrometry (FAAS) was developed for pre-concentration and indirect determination of melamine in milk-based samples. The method is based on the formation of charge transfer sensitive ternary complex among melamine, Mn(II) and Eosin Yin presence of sensitivity enhancer, ionic surfactant cetyltrimethylammonium bromide at pH 4.5, and then extraction of the formed complex into the micellar phase of nonionic surfactant, Triton X-114. After extraction, the surfactant-rich phase was diluted with 1.0 mol L−1 HNO3 in methanol and aspirated into the nebuliser of FAAS for indirect analysis. For optimisation of the variables affecting the ion-pair formation and extraction efficiency, the univariate method was adopted due to its simplicity and ease of use. Under optimal conditions, a good linear relationship was observed from 0.8 to 130 µg L−1 with a detection limit of 0.23 µg L−1. From pre-concentration of 35-mL sample, a pre-concentration factor of 70-fold was obtained with a good sensitivity enhancement (88.5). The accuracy and precision were evaluated as repeatability and intermediate precision with RSD of less than 6.5% with a recovery varied from 92.5% to 98.6%. (n: 5, 5, 25 and 100 µg L−1). The performance of the method from the accuracy and precision studies of two quality control samples was highly good with the precision (4.2–6.0%) and relative recoveries (91.4–96.0%) obtained for spiking levels, 5 and 10 µg L−1. The accuracy, according to two-way ANOVA analysis, was also controlled by two calibrations approaches without any matrix effect in analysis step of samples.
Topics
Citations
OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.
17citationsOpenAlex · cited_by_count (cache / database)
5 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).
- 2022 Development of combined-supramolecular microextraction with ultra-performance liquid chromatography-tandem mass spectrometry procedures for ultra-trace analysis of carbaryl in water, fruits and vegetablesCitations 28 · OpenAlex
- 2020 A simple and quick ionic liquid-based ultrasonic-assisted microextraction for determination of melamine residues in dairy products: Theoretical and experimental approachesCitations 23 · OpenAlex
- 2023 A pH-dependent CT sensitive method for detection of trace Mn in milk by UV-spectrophotometryCitations 3 · OpenAlex
- 2024 Pre-concentration of trace Mn from dairy products through a pH-induced tautomerization/charge transfer complexation before spectrophotometric analysisCitations 0 · OpenAlex
- 2024 Pre‑concentration of trace Mn from dairy products through a pH‑induced tautomerization/charge transfer complexation before spectrophotometric analysisCitations 0 · OpenAlex