Skip to content
akaturk Academic measurement

Article detail · 2006

Effects of mediators on the laccase biosensor response in paracetamol detection

YÖKSİS OpenAlex SJR Q2 JCR Q3 Citations 18 Percentile 67.9% FWCI 0.34
Year
2006
Type
article

Data source split

  • YÖKSİS YÖKSİS article record
  • YÖKSİS venue Biotechnology and Applied Biochemistry
  • Catalog match (ISSN) Biotechnology and Applied Biochemistry
  • OpenAlex OpenAlex enrichment (abstract, citations, topics)

Abstract

OpenAlex · English

An enzyme electrode suitable for paracetamol detection was developed by immobilizing laccase on a dissolved-oxygen probe surface. The immobilization procedure was achieved by means of gelatin, which was then cross-linked with glutaraldehyde. The measurement was based on the detection of oxygen consumption in relation to analyte oxidation. The optimum experimental conditions for the biosensor were investigated and the system was calibrated for paracetamol. Also the effects of three different mediators, namely HBT (1-hydroxybenzotriazole), VLA [violuric acid (5-isonitrosobarbituric acid)] and TEMPO (2,2',6,6'-tetramethylpiperidine-N-oxyl radical) were tested for the biosensor's response. As a result, it was observed that HBT has a remarkable effect on the signal by providing more oxygen consumption during the enzymatic reaction. A linear relationship between sensor responses and analyte concentrations was obtained over the concentration range 2.0-15.0 microM, whereas, in the presence of the mediator HBT, this range became 0.5-3.0 microM.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

18 citations

OpenAlex cited_by_count (cache / database)

11 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).

  1. Electrochemical biosensors for influenza virus a detection: The potential of adaptation of these devices to POC systems 2018 Citations 59 · OpenAlex
  2. Electrochemical biosensors for influenza virus a detection: The potential of adaptation of these devices to POC systems 2018 Citations 59 · OpenAlex
  3. Microfluidic devices and true color sensor as platform for glucose oxidase and laccase assays 2011 Citations 16 · OpenAlex
  4. Microfluidic devices and true color sensor as platform for glucose oxidase and laccase assays 2011 Citations 16 · OpenAlex
  5. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles Biosensing Platform for the Monitoring of Phenolic Compounds 2015 Citations 15 · OpenAlex
  6. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles Biosensing Platform for the Monitoring of Phenolic Compounds 2015 Citations 15 · OpenAlex
  7. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles Biosensing Platform for the Monitoring of Phenolic Compounds 2014 Citations 15 · OpenAlex
  8. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles: Biosensing Platform for the Monitoring of Phenolic Compounds 2014 Citations 15 · OpenAlex
  9. Construction and Comparison ofTrametes versicolorLaccase Biosensors Capable of Detecting Xenobiotics 2010 Citations 10 · OpenAlex
  10. Construction and Comparison of Trametes versicolor Laccase BiosensorsCapable of Detecting Xenobiotics 2010 Citations 10 · OpenAlex

Authors

  1. DİLEK ODACI
  2. SUNA TİMUR EGE ÜNİVERSİTESİ
  3. NURDAN PAZARLIOĞLU
  4. ÜLKÜ ANIK
  5. Azmi Telefoncu