İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2006

Effects of mediators on the laccase biosensor response in paracetamol detection

YÖKSİS OpenAlex SJR Q2 JCR Q3 Atıf 18 Yüzdelik 67.9% FWCI 0.34
Yıl
2006
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • YÖKSİS dergi adı Biotechnology and Applied Biochemistry
  • Katalog eşleşmesi (ISSN) Biotechnology and Applied Biochemistry
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex · İngilizce

An enzyme electrode suitable for paracetamol detection was developed by immobilizing laccase on a dissolved-oxygen probe surface. The immobilization procedure was achieved by means of gelatin, which was then cross-linked with glutaraldehyde. The measurement was based on the detection of oxygen consumption in relation to analyte oxidation. The optimum experimental conditions for the biosensor were investigated and the system was calibrated for paracetamol. Also the effects of three different mediators, namely HBT (1-hydroxybenzotriazole), VLA [violuric acid (5-isonitrosobarbituric acid)] and TEMPO (2,2',6,6'-tetramethylpiperidine-N-oxyl radical) were tested for the biosensor's response. As a result, it was observed that HBT has a remarkable effect on the signal by providing more oxygen consumption during the enzymatic reaction. A linear relationship between sensor responses and analyte concentrations was obtained over the concentration range 2.0-15.0 microM, whereas, in the presence of the mediator HBT, this range became 0.5-3.0 microM.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

18 atıf

OpenAlex cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 11 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. Electrochemical biosensors for influenza virus a detection: The potential of adaptation of these devices to POC systems 2018 Atıf 59 · OpenAlex
  2. Electrochemical biosensors for influenza virus a detection: The potential of adaptation of these devices to POC systems 2018 Atıf 59 · OpenAlex
  3. Microfluidic devices and true color sensor as platform for glucose oxidase and laccase assays 2011 Atıf 16 · OpenAlex
  4. Microfluidic devices and true color sensor as platform for glucose oxidase and laccase assays 2011 Atıf 16 · OpenAlex
  5. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles Biosensing Platform for the Monitoring of Phenolic Compounds 2015 Atıf 15 · OpenAlex
  6. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles Biosensing Platform for the Monitoring of Phenolic Compounds 2015 Atıf 15 · OpenAlex
  7. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles Biosensing Platform for the Monitoring of Phenolic Compounds 2014 Atıf 15 · OpenAlex
  8. Affinity Based Laccase Immobilization on Modified Magnetic Nanoparticles: Biosensing Platform for the Monitoring of Phenolic Compounds 2014 Atıf 15 · OpenAlex
  9. Construction and Comparison ofTrametes versicolorLaccase Biosensors Capable of Detecting Xenobiotics 2010 Atıf 10 · OpenAlex
  10. Construction and Comparison of Trametes versicolor Laccase BiosensorsCapable of Detecting Xenobiotics 2010 Atıf 10 · OpenAlex

Yazarlar

  1. DİLEK ODACI
  2. SUNA TİMUR EGE ÜNİVERSİTESİ
  3. NURDAN PAZARLIOĞLU
  4. ÜLKÜ ANIK
  5. Azmi Telefoncu