Skip to content
akaturk Academic measurement

Article detail · 2020 · article

Engineering plastic gripping mechanism for tension testing of FRP bars

ISSN0021-9983
YÖKSİS OpenAlex
Year2020
Citations8OpenAlex
Percentile%64.7
FWCI0.571.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueJournal of Composite Materials
  • Catalog match (ISSN)Journal of Composite Materials
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

A new grip adaptor, made of an engineering plastic Cast Polyamide 6 (PA6G), was developed for tension testing of FRP reinforcing bars. The new adaptor offers several advantages over conventional anchors, including the ease of application and reuse, being economical, no need for skilled labor, smaller difference between the hardness of the adaptors and sample. Bars with three different diameters (6, 8 and 12 mm), three types of fiber (Carbon, Glass and Basalt) and four types of surface texture (ribbed, wound, fine-sand coated and coarse-sand coated with widely-spaced wrapping) were tested to failure under uniaxial tension. Two identical bars were tested for each combination of parameters (fiber type, surface texture and bar diameter), one with PA6G and the other with grout-filled steel anchors. The tests indicated that the proposed method was able to ensure FRP bars to reach their tensile capacities and fail by rupture without crushing in the gripping regions and pull-out from the jaws of the testing machine. The modulus of elasticity, tensile strength and ultimate strain values of the bars with PA6G anchors were in rather close agreement with the respective values of specimens with conventional steel anchors. This close agreement, i.e. mostly a difference below 5%, implies the success of the proposed method. Among all tested bars, only the ribbed ones failed in the gripping regions in the presence of both anchors as a result of the limited contact surface (rib area), pointing out the need for the use of longer anchors for ribbed bars.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

8citationsOpenAlex · cited_by_count (cache / database)

2 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).

  1. 2023 Effects of fibre wrapping degree and ratio on the tensile properties of carbon FRP-steel hybrid reinforcementsCitations 6 · OpenAlex
  2. 2023 Effects of fibre wrapping degree and ratio on the tensile properties of carbon FRP-steel hybrid reinforcementsCitations 6 · OpenAlex

Authors

3
  1. BOĞAÇHAN BAŞARAN AMASYA ÜNİVERSİTESİ 1
  2. HARUN YAKA AMASYA ÜNİVERSİTESİ 2
  3. İLKER KALKAN 3