Article detail · 2025 · article
Fabrication and fit accuracy of definitive resin fixed partial dentures additively manufactured using different vat polymerization technologies
Data source split
- YÖKSİSYÖKSİS article record
- YÖKSİS venueJournal of Dentistry
- Catalog match (ISSN)Journal of Dentistry
- OpenAlexOpenAlex enrichment (abstract, citations, topics)
- Semantic Scholarcitation count (not merged with OpenAlex)
Abstract
OBJECTIVES: To investigate the fabrication and fit accuracy of three-unit definitive resin fixed partial dentures (FPDs) manufactured with different vat polymerization technologies, and to compare them with those manufactured subtractively. METHODS: A total of 48 three-unit posterior fixed partial dentures (FPDs) were fabricated either additively from a resin intended for definitive use (VarseoSmile Triniq) with low force display (Form 4B, AM-LFD), digital light processing (Max UV, AM-DLP), and liquid crystal display (SOL, AM-LCD) technologies, or subtractively from high-impact polymer composite (breCAM.HIPC, SM) (n = 12). After digitally assessing the external, internal, and marginal surface deviations and average gaps (fit), one-way analysis of variance (ANOVA) and Tukey tests were used for the statistical analyses. Precision was defined as the average of measured values from the mean value, and was analyzed with one-way ANOVA (α = 0.05). RESULTS: SM and AM-LCD specimens had the highest external deviations, whereas AM-LFD specimens had the lowest (P < 0.001). AM-LCD specimens had the highest and SM specimens had the lowest intaglio deviations (P < 0.001). SM specimens had the highest marginal deviations (P ≤ 0.001). Gap values decreased in the order of AM-LCD, AM-LFD, AM-DLP, and SM (P < 0.001). Tested specimens' precision was similar (P ≥ 0.079). CONCLUSIONS: AM-LFD mostly led to lower trueness than the other printers and SM FPDs had the lowest marginal trueness. Tested FPDs had higher gaps than the cement space; however, SM FPDs had clinically acceptable fit, while additively manufactured FPDs exceeded clinical gap thresholds regardless of the printer. CLINICAL SIGNIFICANCE: Posterior three-unit definitive fixed partial dentures fabricated with the tested resin and printers may be alternatives to those subtractively manufactured from high-impact polymer composite, given the small surface deviation differences. However, potential fit issues should be considered when a 100 µm cement space is used.
Topics
Citations
OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.
9citationsOpenAlex · cited_by_count (cache / database)
8 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).
- 2026 Accuracy and Fit of Three-Unit Dental Restorations Fabricated from 3D-Printed Resins and CAD/CAM Milling Materials: A Micro-CT StudyCitations 2 · OpenAlex
- 2026 Wear, fracture strength, and reliability of three-unit definitive fixed dental prostheses fabricated with different vat polymerization methodsCitations 1 · OpenAlex
- 2026 Fracture load of cantilevered implant‐supported prostheses of varying heights fabricated from additively and subtractively manufactured resinsCitations 0 · OpenAlex
- 2026 Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prosthesesCitations 0 · OpenAlex
- 2026 Fracture load of cantilevered implant‐supported prostheses of varying heights fabricated from additively and subtractively manufactured resinsCitations 0 · OpenAlex
- 2026 Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prosthesesCitations 0 · OpenAlex
- 2026 Influence of printing orientation on the mechanical and surface characteristics of a novel 3D-printed definitive resin-based compositeCitations 0 · OpenAlex
- 2026 Influence of printing orientation on the mechanical and surface characteristics of a novel 3D-printed definitive resin-based compositeCitations 0 · OpenAlex