Skip to content
akaturk Academic measurement
Search

Article detail · 2025 · article

Computer Vision–Based Artificial Intelligence Tool for Direct Bilirubin Jaundice Measurement in Newborns

ISSN0730-4625
YÖKSİS OpenAlex
Year2025
Citations0OpenAlex
Percentile%33.1
FWCI0.01.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueDimensions of Critical Care Nursing
  • Catalog match (ISSN)Dimensions of Critical Care Nursing
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

BACKGROUND: Conjugated hyperbilirubinemia, characterized by elevated levels of direct bilirubin (DB) may indicate underlying hepatobiliary disorders, such as biliary atresia, and warrants further investigation. OBJECTIVES: The aim of this study was to accurately measure jaundice, related to DB levels, in newborn infants using an artificial intelligence (AI)-based computer vision tool. METHOD: The computer vision tool used data processing, color transformations, and contrast enhancement techniques. Additionally, a convolutional neural network was created to predict DB levels. The study included 80 infants for training and validation and 17 infants for retesting. Five photographs were taken from the face, neck-chest, abdomen, extremities, and back after blood was drawn to measure DB levels. The photographs were captured using a professional camera under white light in the neonatal intensive care unit. Data analysis involved calculating the margin of error, percentage margin of error, and correlation statistics. RESULTS: The retest findings were analyzed to determine the margins of error. The study revealed a 5.24% discrepancy between the AI-based computer vision tool and the DB values obtained from laboratory blood tests. Furthermore, a positive correlation was observed between patient blood values and the mean calculated by the AI system. DISCUSSION: This study concluded that DB measurements, conducted under appropriate conditions, were accurately determined using AI with a good level of precision. Subsequent research on total bilirubin is recommended.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

0citationsOpenAlex · cited_by_count (cache / database)

Authors

4
  1. SUAT TUNCAY 1
  2. GÜRKAN ÖZDEN 2
  3. ABDULLAH SARMAN 3
  4. FATMA GÜDÜCÜ TÜFEKCİ ATATÜRK ÜNİVERSİTESİ 4