A Multicenter Analysis of Subjectivity of Indirect Immunofluorescence Test in Antinuclear Antibody Screening

ISSN2148-5046
YÖKSİS OpenAlex Open access · diamond
Year2019
Citations6OpenAlex
Percentile%66.4
FWCI0.51.00 = world average
Scopus (SJR)Q4
WoS (JCR)Q4

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueArchives of Rheumatology
  • Catalog match (ISSN)Archives of Rheumatology
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

Objectives: This study aims to evaluate the interpretation of the antinuclear antibody (ANA)-indirect immunofluorescence (IIF) test results based on the interpreter-related subjectivity and to examine the inter-center agreement rates with the performance of each laboratory. Patients and methods: The ANA-IIF testing was carried out in a total of 600 sera and evaluated by four laboratories. The inter-center agreement rates were detected. The same results given by the four centers were accepted as gold standard and the predictive values of each center were calculated. Results: The inter-center agreement was reported for ANA-IIF test results from 392 of 600 (65.3%) sera, while 154 of 392 results were positive. Four study centers reported 213 (35.5%), 222 (37.0%), 266 (44.3%), and 361 (60.2%) positive test results, respectively. In terms of the patterns, the highest and lowest positive predictive values were 72.3% and 42.7%, respectively, while the highest and lowest negative predictive values were 99.6% and 61.5%, respectively. The agreement for semi-quantitative evaluation at three levels of fluorescence intensity stated by four centers was detected in 100 sera at 87% 3(+), while the other two levels were 6% and 7%. The highest predictive value for the highest fluorescence intensity of 3(+) was found to be 71.9%. Conclusion: Significant differences may be observed among laboratories in terms of qualitative results, patterns, and semi-quantitative determination of the fluorescence intensity in the ANA-IIF testing, particularly at low fluorescence intensity levels and in those with speckled patterns. In case of any discrepancy between ANA-IIF test and clinical prediagnosis, the test should be repeated in another laboratory, if necessary.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

6citationsOpenAlex · cited_by_count (cache / database)

Authors

7
  1. VİLDAN TURAN FARAŞAT 1
  2. TALAT ECEMİŞ 2
  3. YAVUZ DOĞAN DOKUZ EYLÜL ÜNİVERSİTESİ 3
  4. Aslı Gamze Şener 4
  5. GÜLFEM ECE 5
  6. Pınar Erbay Dündar 6
  7. TAMER ŞANLIDAĞ 7