Skip to content
akaturk Academic measurement

Article detail · 2023 · article

Calculated Globulin Is Clinically Useful as a Screening Test for Antibody Deficiency in Turkish Adult Patients

YÖKSİS OpenAlex
Year2023
Citations10OpenAlex
Citations10Semantic Scholar · 2 influential
Percentile%71.3
FWCI0.891.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueInternational Archives of Allergy and Immunology
  • Catalog match (ISSN)International Archives of Allergy and Immunology
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

INTRODUCTION: Heterogeneous clinical features of antibody deficiency (AD) may cause diagnostic delays. Calculated globulin (CG) (total protein minus albumin) has been proposed as a screening test to prevent morbidity due to diagnostic delays in AD. Our aim was to validate CG as a screening test for AD in Turkish adult patients by comparing its role with gamma globulin analysis in protein electrophoresis. METHODS: Fifty serum samples were randomly collected for each level of CG from 15 to 25 g/L and tested for serum IgG, IgA, IgM levels and protein electrophoresis. Cut-off values predicting low IgG levels were calculated for electrophoretically determined gamma globulin and CG. Additionally, the data of 47 patients followed up in our clinic with a diagnosis of primary antibody deficiency (PAD) were retrospectively analyzed. RESULTS: A total of 550 adult patients were included in the study. The CG value predicting patients with IgG <6 g/L as a screening test was determined as <20 g/L with 83.8% sensitivity and 74.9% specificity. The gamma globulin value which predicted patients with the same IgG value of 89.0% sensitivity and 89.4% specificity was determined as <7 g/L. In the retrospective analysis, 37 of 47 patients (78.7%) with PAD had a CG value of <20 g/L at the time of the diagnosis and all 13 patients (100%) whose gamma globulin values were measured at the time of the diagnosis had a gamma globulin value of <7 g/L. CONCLUSION: The determined CG cut-off value of <20 g/L can be used as a screening test in Turkish adult patients.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

10citationsOpenAlex · cited_by_count (cache / database)

Authors

11
  1. PELİN KARADAĞ 1
  2. DENİZ EYİCE KARABACAK 2
  3. NİDA ÖZTOP UZ 3
  4. ŞENGÜL BEYAZ BELKAYA 4
  5. ÖZDEMİR CAN TÜZER 5
  6. SEMRA DEMİR 6
  7. DERYA ERDOĞDU 7
  8. HALİM İŞSEVER 8
  9. NİLGÜN SEMA GENÇ 9
  10. BEYHAN ÖMER İSTANBUL SAĞLIK VE TEKNOLOJİ ÜNİVERSİTESİ 10
  11. ASLI AKKOR 11