Adaptive backstepping control design for ATMD systems in nonlinear structures with nonlinear disturbance and parametric uncertainties
Journal
Journal of Vibration and ControlISSN 1077-5463
The ISSN points to another catalog journal; the name is from the YÖKSİS record.
- Year
- 2024
- Type
- article
Data source split
- YÖKSİS YÖKSİS article record
- YÖKSİS venue Journal of Vibration and Control
- Catalog match (ISSN) JVC/Journal of Vibration and Control
- OpenAlex OpenAlex enrichment (abstract, citations, topics)
Abstract
OpenAlex · English
Active tuned mass damper (ATMD) devices are recommended in various structures to reduce vibrations. The performance of the ATMD system is closely tied to the control design utilized, according to research in the literature. The designed control input will take into account as much system dynamics as possible, making it possible to use it as a generalized controller in all similar systems. Nonlinear behavior is the natural behavior of engineering structures, and in order to obtain a more realistic and high-performance ATMD system, it can be considered as an appropriate approach to design the controller by considering the structural nonlinearities. In addition, unexpected external influences and parameter uncertainties must be taken into account during control design to ensure that control systems perform successfully in similar systems in all conditions. Therefore, in this study, the nonlinear model of the multi-story building was reconstructed by adding nonlinear disturbance to represent unknown external effects. Band-limited white noise is used as a disturbance function and Gaussian white noise is added to measured states in this study. To obtain a robust controller, unknown structural parameters are compensated for by using adaptive compensation terms. With the controller design supported by the Lyapunov-based stability analysis, the stability of the vibrating structure featuring an ATMD is theoretically guaranteed while achieving the main control goal. Performance analyses of the designed controllers are carried out with simulation studies. The efficiency of the developed Lyapunov-based controller in dampening the unwanted vibrations that occurred on the building is seen in simulation results.
Topics
Citations
OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.
6 citations
OpenAlex cited_by_count (cache / database)
3 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).
- A novel linear regression model based controller design for the active tuned mass damper system of multi-story building structures 2025
- A novel linear regression model based controller design for the active tuned mass damper system of multi-story building structures 2025
- Advanced dimensional analysis for robust control of benchmark structural system via generalized linear matrix inequalities 2026