Article detail · 2020 · article
Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature
Data source split
- YÖKSİSYÖKSİS article record
- YÖKSİS venueRestorative Dentistry Endodontics
- Catalog match (ISSN)Restorative Dentistry and Endodontics
- OpenAlexOpenAlex enrichment (abstract, citations, topics)
Abstract
Objectives: This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature. Materials and Methods:In total, 80 VDW.ROTATE (25/0.04),TruNatomy (26/0.04),2Shape (25/0.04),and HyFlex CM (25/0.04)NiTi rotary files (n = 20 in each group) were subjected to static cyclic fatigue testing at body temperature (37°C) in stainless-steel artificial canals prepared according to the size and taper of the instruments until fracture occurred.The number of cycles to fracture (NCF) was calculated, and the lengths of the fractured fragments were measured.The data were statistically analyzed using a 1-way analysis of variance and post hoc Tamhane tests at the 5% significance level (p < 0.05).Results: There were significant differences in the cyclic fatigue resistance among the groups (p < 0.05), with the highest to lowest NCF values of the files as follows: VDW.ROTATE, HyFlex CM, 2Shape, and TruNatomy.There was no significant difference in the lengths of the fractured fragments among the groups.The scanning electron microscope images of the files revealed typical characteristics of fracture due to cyclic fatigue.Conclusions: The VDW.ROTATE files had the highest cyclic fatigue resistance, and the TruNatomy and 2Shape files had the lowest cyclic fatigue resistance in artificial canals at body temperature.
Topics
Citations
OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.
31citationsOpenAlex · cited_by_count (cache / database)
8 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).
- 2024 Effect of Temperature on the Cyclic Fatigue Resistance and Phase Transformation Behavior of Three Different NiTi Endodontic InstrumentsCitations 4 · OpenAlex
- 2023 Evaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopyCitations 1 · OpenAlex
- 2023 Evaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopyCitations 1 · OpenAlex
- 2023 Effect of Sodium Hypochlorite and Hypochlorous Acid Solutions on the Cyclic Fatigue Resistance of Waveonegold, K3XF and Hyflex-EDM: A Study of Metallurgical PropertiesCitations 1 · OpenAlex
- 2023 Effect of Sodıum Hypochlorıte and Hypochlorous Acıd Solutıonson the Cyclıc Fatıgue Resıstance of Waveonegold, K3xf and Hyflex-EdmCitations 1 · OpenAlex
- 2023 Effect of Sodium Hypochlorite and Hypochlorous Acid Solutions on the Cyclic Fatigue Resistance of Waveonegold, K3XF and Hyflex-EDM A Study of Metallurgical PropertiesCitations 1 · OpenAlex
- 2023 Evaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopyCitations 1 · OpenAlex
- 2022 Comparison of canal transportations and centering ability of rotary instrument systems with different heat-treated NiTi alloys: An in vitro CBCT studyCitations 0 · OpenAlex