Skip to content
akaturk Academic measurement

Article detail · 2017

Biomechanical Comparison of Transoral and Transbuccal Lateral Cortical Plate Fixation For the Management of Mandibular Angle Fractures

Journal

Nigerian Journal of Clinical Practice

ISSN 1119-3077

YÖKSİS OpenAlex Open access · diamond SJR Q3 JCR Q4 Citations 5 Percentile 64.0% FWCI 0.3
Year
2017
Type
article

Data source split

  • YÖKSİS YÖKSİS article record
  • YÖKSİS venue Nigerian Journal of Clinical Practice
  • Catalog match (ISSN) Nigerian Journal of Clinical Practice
  • OpenAlex OpenAlex enrichment (abstract, citations, topics)

Abstract

English (OpenAlex)

OBJECTIVES: The purpose of this experimental study was to compare the biomechanical behaviors of two different types of osteosynthesis that are used in the treatment of mandibular angle fractures. MATERIALS AND METHODS: Twenty synthetic polyurethane human mandible replicas, with medullar and cortical portions, were used in this study. These polyurethane hemimandibles were randomly divided into two groups (n = 10). The transbuccal group (Group A) was fixed with 7 mm long self-tapping 2.0 mm titanium screws at 85° to the reference line and the transoral group (Group B) was fixed with the same screws at 15° to the reference line. All testings were performed on a servo-hydraulic testing machine. The data were transmitted directly from the load cell to a computer, which showed the emergent results of the material characteristics under resisted forces as a graphic containing force and displacement. The peak point loading and displacement for each subject were measured. RESULTS: The comparison between the groups was analyzed with an independent-samples t-test, and P < 0.05 was considered to be significant. The results show that there were no significant differences between the groups for the peak loads and displacement values at the peak loads. CONCLUSION: The results of this experimental study demonstrated that there were no significant differences between the transbuccal and transoral methods in terms of fixation stability. In other words, the screw position and angle seemed to no have influence on the fixation stability in single miniplate treatments of a mandibular angle fracture.

Topics

  • Facial Trauma and Fracture Management
  • Spinal Fractures and Fixation Techniques
  • Dental Radiography and Imaging

Primary topic Facial Trauma and Fracture Management

Authors

  1. MEHMET MELİH ÖMEZLİ
  2. FERHAT AYRANCI
  3. MEHMET EMRAH POLAT HARRAN ÜNİVERSİTESİ
  4. ERTUNÇ DAYI
  5. HÜCCET KAHRAMANZADE
  6. SERAP KARAGÖL YALÇIN ONDOKUZ MAYIS ÜNİVERSİTESİ