Skip to content
akaturk Academic measurement

Article detail · 2013 · article

Evaluation of Atrial Electromechanic Delay and Left Atrial Mechanical Functions in the Patients with Secundum Type Atrial Septal Defect

Journal Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques The ISSN points to another catalog journal; the name is from the YÖKSİS record.
ISSN0742-2822
YÖKSİS OpenAlex SJR Q2 JCR Q3
Year2013
Citations11OpenAlex
Percentile%74.0
FWCI0.741.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueEchocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques
  • Catalog match (ISSN)Echocardiography
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)

Abstract

OpenAlex English

AIM: The aim of our study was to evaluate atrial electromechanical delay (AEMD) and left atrial mechanical functions (LAMF) in the patients with secundum-type atrial septal defect (ASD). METHOD: We included 72 patients with secundum type ASD in the study group and 35 gender and age-matched healthy volunteers for the control group. Maximal, minimal, and presystolic LA volumes were measured by modified Simpson method and indexed to the body surface area (BSA). Inter-AEMD, right and left intra-AEMD were measured from the lateral and septal mitral annulus and tricuspid annulus using tissue Doppler imaging (TDI). RESULTS: The age, gender, systolic and diastolic blood pressure, heart rate (HR), BSA, and body mass index (BMI) parameters were not significantly different between the groups. Left atrial active and total emptying fractions and conduit volumes were significantly lower in the patients with ASD compared with the control group (P = 0.006, P = 0.001, and P = 0.032, respectively). Total emptying volume was increased in patients with ASD (P = 0.021). Passive emptying volume and fraction and active emptying volumes were not different significantly between the groups (P > 0.05). The left intraatrial, right intraatrial, and inter-AEMDs were significantly longer in the ASD group (P = 0.032, P = 0.013, and P = 0.003, respectively). CONCLUSION: The left atrial reservoir and contractile pump functions are reduced; the left intraatrial, right intraatrial, and inter-AEMDs are increased in the patients with ASD.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

11citationsOpenAlex · cited_by_count (cache / database)

8 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).

  1. 2014 Effects of percutaneous closure of atrial septal defect on left atrial mechanical and conduction functionsCitations 31 · OpenAlex
  2. 2014 Effects of percutaneous closure of atrial septal defect on left atrial mechanical and conduction functionsCitations 31 · OpenAlex
  3. 2014 Effects of percutaneous closure of atrial septal defect on left atrial mechanical and conduction functionsCitations 31 · OpenAlex
  4. 2014 Effects of percutaneous closure of atrial septal defect on left atrial mechanical and conduction functionsCitations 31 · OpenAlex
  5. 2019 Long term evaluation of electromechanical delay in patients with atrial septal defect after transcatheter closureCitations 11 · OpenAlex
  6. 2018 Long term evaluation of electromechanical delay in patients with atrial septal defect after transcatheter closureCitations 11 · OpenAlex
  7. 2019 Long term evaluation of electromechanical delay in patients with atrial septal defect after transcatheter closureCitations 9 · OpenAlex
  8. 2016 The atrial conduction time in patients with normal atrial sizeCitations 1 · OpenAlex

Authors

10
  1. MEHMET ERTÜRK 1
  2. MUZAFFER ASLAN SİİRT ÜNİVERSİTESİ 2
  3. HALE ÜNAL AKSU 3
  4. İBRAHİM FARUK AKTÜRK 4
  5. MEHMET GÜL 5
  6. FATİH UZUN 6
  7. ÖZGÜR SÜRGİT 7
  8. HASAN ARI 8
  9. NEVZAT USLU 9
  10. MUSTAFA KEMAL EROL 10