Article detail · 2013
Short and long term complications of device closure of atrial septal defect and patent foramen ovale: Meta-analysis of 28,142 patients from 203 studies
- Year
- 2013
- Type
- article
Data source split
- YÖKSİS YÖKSİS article record
- YÖKSİS venue Catheterization and Cardiovascular Interventions
- Catalog match (ISSN) Catheterization and Cardiovascular Interventions
- OpenAlex OpenAlex enrichment (abstract, citations, topics)
Abstract
OpenAlex · English
BACKGROUND: Device closure of atrial septal defect (ASD) and patent foramen ovale (PFO) are both associated with short- and long-term complications. Our knowledge of the complication rates of ASD and PFO closure is limited. Our objective was to review the peri-procedural and long-term complications of ASD and PFO closure. METHODS: Medline, EMBASE, and Scopus databases were searched between 1973 and 2012. A total of 28,142 patients from 203 case series were included. Of these 203 articles, 111 were reporting ASD closure, 61 were reporting PFO closure, and 31 were reporting both. Pooled incidence rates of cardiac complications were calculated separately for peri-procedural and at follow-up. RESULTS: Peri-procedural major complications were reported from 0% to 9.4%, with a pooled estimate rate of 1.4% (95% CI: 1.3-1.6%). It was 1.6% (95% CI: 1.4-1.8%) in ASD group, 1.1% (95% CI: 0.9-1.3%) in PFO group, and 1.3% (95% CI: 0.9-1.9%) in ASD/PFO group. The most common major complication was the device embolization requiring surgery. Peri-procedural minor complications were reported with a pooled estimate rate of 1.4% (95% CI: 1.2-1.7%). It was 1.6% (95% CI: 1.2-2.1%) in ASD group, 1.3% (95% CI: 1.0-1.7%) in PFO group, and 1.5% (95% CI: 1.1-1.2.1%) in ASD/PFO group. The most frequent major complications at follow-up were cerebrovascular events [1.3% (95% CI: 1.1-1.6%)] and device thrombosis [1.2% (95% CI: 1.0-1.4%)]. Both were more frequent in PFO group. CONCLUSION: Device closure of ASD and PFO are associated with non-negligible serious complications, both in early and long-term.
Topics
Citations
OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.
159 citations
OpenAlex cited_by_count (cache / database)
5 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).
- Safety and efficacy of device closure for patent foramen ovale for secondary prevention of neurological events: Comprehensive systematic review and meta-analysis of randomized controlled trials 2013
- Transcatheter closure vs totally endoscopic robotic surgery for atrial septal defect closure: A single‐center experience 2020
- Transcatheter closure vs totally endoscopic robotic surgery for atrial septal defect closure: A single‐center experience 2020
- Early and Mid-Term Follow-Up Results After Transcatheter Closure of Secundum Atrial Septal Defect 2022
- Streamlined percutaneous atrial septal defect closure in adults 2020