Skip to content
akaturk Academic measurement

Article detail · 2023

A Flexible and Biodegradable Piezoelectric-Based Wearable Sensor for Non-Invasive Monitoring of Dynamic Human Motions and Physiological Signals

Journal

Advanced Materials Technologies

ISSN 2365-709X

YÖKSİS OpenAlex Open access · bronze SJR Q1 Citations 97 Top 10% Percentile 98.7% FWCI 7.74
Year
2023
Type
article

Data source split

  • YÖKSİS YÖKSİS article record
  • YÖKSİS venue Advanced Materials Technologies
  • Catalog match (ISSN) Advanced Materials Technologies
  • OpenAlex OpenAlex enrichment (abstract, citations, topics)

Abstract

OpenAlex · English

Abstract Recent progress in flexible sensors and piezoelectric materials has enabled the development of continuous monitoring systems for human physiological signals as wearable and implantable medical devices. However, their non‐degradable characteristics also lead to the generation of a significant amount of non‐decomposable electronic waste (e‐waste) and necessitate a secondary surgery for implant removal. Herein, a flexible and biodegradable piezoelectric material for wearable and implantable devices that addresses the problem of secondary surgery and e‐waste while providing a high‐performance platform for continuous and seamless monitoring of human physiological signals and tactile stimuli is provided. The novel composition of bioresorbable poly( l ‐lactide) and glycine leads to flexible piezoelectric devices for non‐invasive measurement of artery pulse signals in near‐surface arteries and slight movement of the muscle, including the trachea, esophagus, and movements of joints. The complete degradability of piezoelectric film in phosphate‐buffered saline at 37 °C is also shown. The developed pressure sensor exhibits high sensitivity of 13.2 mV kPa −1 with a response time of 10 ms and shows good mechanical stability. This piezoelectric material has comparable performance to commonly used non‐degradable piezoelectric materials for measuring physiological signals. It can also be used in temporary implantable medical devices for monitoring due to its degradable nature.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

97 citations

OpenAlex cited_by_count (cache / database)

1 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).

  1. Piezoelectric transducer-assisted mass normalization of mode shapes in thin-walled structures 2025 Citations 2 · OpenAlex

Authors

  1. Mohsin Ali
  2. Seyed Morteza Hoseyni
  3. Ritu Das
  4. Muhammed Awais
  5. FATMA İPEK BAŞDOĞAN KOÇ ÜNİVERSİTESİ
  6. LEVENT BEKER KOÇ ÜNİVERSİTESİ