Skip to content
akaturk Academic measurement

Article detail · 2017

Importance of Physical and Physiological Parameters in Simulated Particle Transport in the Alveolar Zone of the Human Lung

Journal

Applied Sciences

ISSN 2076-3417

The ISSN points to another catalog journal; the name is from the YÖKSİS record.

YÖKSİS OpenAlex Open access · gold SJR Q2 JCR Q3 Citations 7 Percentile 62.3% FWCI 0.38
Year
2017
Type
article

Data source split

  • YÖKSİS YÖKSİS article record
  • YÖKSİS venue Applied Sciences
  • Catalog match (ISSN) Applied Sciences (Switzerland)
  • OpenAlex OpenAlex enrichment (abstract, citations, topics)

Abstract

English (OpenAlex)

The trajectory and deposition efficiency of micron-sized (1–5 µm) particles, inhaled into the pulmonary system, are accurately determined with the aid of a newly developed model and modified simulation techniques. This alveolar model, which has a simple but physiologically appropriate geometry, and the utilized fluid structure interaction (FSI) methods permit the precise simulation of tissue wall deformation and particle fluid interactions. The relation between tissue movement and airflow in the alveolated duct is solved by a two-way fluid structure interaction simulation technique, using ANSYS Workbench (Release 16.0, ANSYS INC., Pittsburgh, PA, USA, 2015). The dynamic transport of particles and their deposition are investigated as a function of aerodynamic particle size, tissue visco-elasticity, tidal breathing period, gravity orientation and particle–fluid interactions. It is found that the fluid flows and streamlines differ between the present flexible model and rigid models, and the two-way coupling particle trajectories vary relative to one-way particle coupling. In addition, the results indicate that modelling the two-way coupling particle system is important because the two-way discrete phase method (DPM) approach despite its complexity provides more extensive particle interactions and is more reliable than transport results from the one-way DPM approach. The substantial difference between the results of the two approaches is likely due to particle–fluid interactions, which re-suspend the sediment particles in the airway stream and hence pass from the current generation.

Topics

  • Inhalation and Respiratory Drug Delivery
  • Aerosol Filtration and Electrostatic Precipitation
  • Cyclone Separators and Fluid Dynamics

Primary topic Inhalation and Respiratory Drug Delivery

Authors

  1. DOĞAN ÇİLOĞLU ATATÜRK ÜNİVERSİTESİ
  2. Hassan Athari
  3. ABDURRAHİM BÖLÜKBAŞI
  4. Marc Rosen