Skip to content
akaturk Academic measurement

Article detail · 2023 · article

Evaluation of the Effect of Transcatheter Aortic Valve Implantation on Left Ventricular Function by 4-Dimensional Echocardiography

Journal Archives of the Turkish Society of Cardiology The ISSN points to another catalog journal; the name is from the YÖKSİS record.
ISSN1016-5169
YÖKSİS OpenAlex Open access · diamond TR Index
Year2023
Citations2OpenAlex
Percentile%59.4
FWCI0.341.00 = world average
Scopus (SJR)Q3
WoS (JCR)Q4

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueArchives of the Turkish Society of Cardiology
  • Catalog match (ISSN)Turk Kardiyoloji Dernegi Arsivi
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

OBJECTIVE: Beneficial effects of transaortic valve implantation on left ventricular hemodynamics and prognosis of patients have been demonstrated. Although left ventricular systolic and diastolic function following transaortic valve implantation procedure have been examined in previous studies, 4-dimensional echocardiographic parameters have not been extensively studied, especially in patients with preserved ejection fraction aortic stenosis. In our study, we planned to evaluate the effect of transaortic valve implantation on myocardial deformation using 4-dimensional echocardiography. METHODS: A total of 60 consecutive patients who underwent transaortic valve implantation for severe aortic stenosis with preserved ejection fraction were prospectively enrolled in the study. Standard 2-dimensional echocardiography and 4-dimensional echocardiography were performed in all patients before and 6 months after the transaortic valve implantation procedure. RESULTS: Six months after valve implantation, significant improvement was observed in global longitudinal strain (P < 0.001), spherical circumferential strain (P = 0.022), global radial strain (P = 0.008), and global area strain (P < 0.001). In the regression analysis, global area strain and absence of diabetes mellitus were determined as independent predictors to show a 10% increase in the left ventricular ejection fraction. CONCLUSIONS: In patients with preserved ejection fraction who underwent transaortic valve implantation, left ventricle deformation parameters have improved after 6 months, especially by using 4-dimensional echocardiography. The use of 4-dimensional echocardiography should be more common in daily practice.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

2citationsOpenAlex · cited_by_count (cache / database)

Authors

10
  1. ADİL BAYRAMOĞLU 1
  2. ZEYNEP ULUTAŞ İNÖNÜ ÜNİVERSİTESİ 2
  3. JÜLİDE AKAYCAN 3
  4. ŞIHO HİDAYET 4
  5. MEHMET HAKAN TAŞOLAR 5
  6. MEHMET CANSEL 6
  7. NECİP ERMİŞ 7
  8. MUHAMMED ERKAM CENGİL 8
  9. FATİH GÜVEN 9
  10. HASAN PEKDEMİR 10