Skip to content
akaturk Academic measurement
For academics Sign in Sign up

Article detail · 2021

Cyclic Fatigue Resistance and Shaping Ability of Heat Treated Nickel-titanium Instruments after Repeated Use

Journal

Nigerian Journal of Clinical Practice

ISSN 1119-3077

YÖKSİS OpenAlex Open access · diamond SJR Q3 JCR Q4 Citations 9 Percentile 80.8% FWCI 1.53
Year
2021
Type
article

Data source split

  • YÖKSİS YÖKSİS article record
  • YÖKSİS venue Nigerian Journal of Clinical Practice
  • Catalog match (ISSN) Nigerian Journal of Clinical Practice
  • OpenAlex OpenAlex enrichment (abstract, citations, topics)

Abstract

OpenAlex · English

AIMS: To evaluate the effect of multiple-use and sterilization on cyclic fatigue and shaping ability of heat-treated nickel-titanium (NiTi) rotary instruments. METHODS: A total of 120 acrylic blocks with S-shaped canals were photographed and prepared by HyFlex CM, ProTaper Next, and Twisted File. Ten new sets of each rotary instruments were used for four times. The autoclaving process was repeated after each use. Pre- and post instrumentation images were superimposed. The amount of resin removal and canal transportation by each system was measured in eleven different points. Instruments were subsequently subjected to a cyclic fatigue test in a double-curved artificial canal. The means and standard deviations of the number of cycles to failure (NCF) were calculated and statistically analyzed (P < 0.05). RESULTS: No fractures occurred during the shaping of the simulated canals. The ProTaper Next removed the greatest amount of resin, whereas the Twisted File had the lowest values at all levels. Repeated clinical use and sterilization resulted in a decrease in the resin removal at most levels in Twisted File and ProTaper Next. In terms of canal transportation, an increase in a limited number of levels was detected after repeated use of all rotary files. Twisted File had the greatest cyclic fatigue resistance, followed by HyFlex CM and ProTaper Next (P < 0.05). CONCLUSIONS: The effects of repeated use and autoclaving on the cyclic fatigue resistance of HyFlex CM, ProTaper Next, and Twisted File were not significant. Canal transportation increased mostly in the apical region. The amount of resin removal decreased as the number of use increased for ProTaper Next and Twisted File instruments.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

9 citations

OpenAlex cited_by_count (cache / database)

1 publications in the local catalog that cite this work (OpenAlex reference match; not the full global list).

  1. Evaluation of shaping performance and surface changes of two different minimally invasive shaping file systems used in resin blocks 2023 Citations 0 · OpenAlex

Authors

  1. SELIN GOKER
  2. DİLEK TÜRKAYDIN MARMARA ÜNİVERSİTESİ