Skip to content
akaturk Academic measurement

Article detail · 2025 · article

Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique

YÖKSİS OpenAlex Open access · gold TR Index
Year2025
Citations1OpenAlex
Percentile%71.8
FWCI0.911.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueActa Orthopaedica et Traumatologica Turcica
  • Catalog match (ISSN)Acta Orthopaedica et Traumatologica Turcica
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

Objective: This study aimed to compare the biomechanical characteristics of conventional transosseous equivalent (TOE) techniques with those of the novel free independent double-row medial fixation method, using rigid polyurethane (PU) foam blocks to simulate osteoporotic humerus bone. Methods: In this biomechanical study, 4 groups were tested using rigid PU foam blocks with osteoporotic properties and bovine infraspinatus tendons to simulate the rotator cuff. Groups 1 and 2 employed conventional TOE techniques: medial row knotted repair and knotless repair, respectively. Groups 3 and 4 utilized the "free independent double-row medial fixation method," differing in the order of suture tying. Several biomechanical characteristic and pressure parameters were measured. Results: Groups 3 (0.16 ± 0.04 MPa) and 4 (0.17 ± 0.05 MPa) achieved significantly higher initial contact pressure compared to standard TOE techniques (P=.039). While contact area (Group 3: 102.4 ± 55.0 mm², Group 4: 110.4 ± 37.2 mm²) and ultimate failure force (Group 3: 212.0 ± 26.5 N, Group 4: 214.7 ± 30.2 N) were relatively higher, the differences were not statistically significant (P=.135 and P=.3, respectively). The overall failure types included medial anchor pullout (40%) and suture/tendon stripping (32.5%), with no significant differences among groups (P=.260). Conclusion: With superior contact pressure and comparable ultimate failure and contact area measurements, the novel independent double-row medial fixation technique may be a viable alternative to conventional TOE techniques for enhancing medial row stability in osteoporotic conditions. Level of Evidence: N/A.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

1citationsOpenAlex · cited_by_count (cache / database)

Authors

6
  1. Hasan Eskara 1
  2. AHMET KESKİN 2
  3. YAŞAR TATAR MARMARA ÜNİVERSİTESİ 3
  4. NEJLA GERÇEK 4
  5. YUNUS İMREN 5
  6. SÜLEYMAN SEMİH DEDEOĞLU 6