OpenAlex 594 eser 10 yazar konusu
Çalışmalar
594 eser
-
OpenAlex üst %10
OpenAlex 98.2%
Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT a…
-
OpenAlex üst %1
OpenAlex 99.2%
Intravascular ultrasound (IVUS) and intracardiac echography (ICE) catheters with real-time volumetric ultrasound imaging capability can provide unique benefits to many interventional procedures used in the diagnosis and treatment of coronary and structural heart diseases. Integration of capacitive micromachined ultras…
-
OpenAlex üst %10
OpenAlex 95.6%
In real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large number of ultrasound channels. The coarray (spatial convolution of the transmit and receive arrays…
-
YÖKSİS
SJR Q1
JCR Q4
OpenAlex üst %10
OpenAlex 93.2%
We present the four key areas of research-preprocessing, the volume conductor, the forward problem, and the inverse problem-that affect the performance of EEG and MEG source imaging. In each key area we identify prominent approaches and methodologies that have open issues warranting further investigation within the co…
-
YÖKSİS
SJR Q1
JCR Q1
OpenAlex 79.7%
Four methods of range measurement for airborne ultrasonic systems - namely simple thresholding, curve-fitting, sliding-window, and correlation detection - are compared on the basis of bias error, standard deviation, total error, robustness to noise, and the difficulty/complexity of implementation. Whereas correlation…
-
YÖKSİS
SJR Q1
JCR Q1
OpenAlex üst %10
OpenAlex 95.8%
Monitoring the electrical activity inside the human brain using electrical and magnetic field measurements requires a mathematical head model. Using this model the potential distribution in the head and magnetic fields outside the head are computed for a given source distribution. This is called the forward problem of…
-
OpenAlex 75.8%
BACKGROUND: Skinfold thickness (SFT) and bioelectrical impedance (BIA) are readily available and commonly used techniques in patient monitoring for body composition analysis (BCA) in clinical practise. Another one, dual-energy X-ray absorptiometry (DEXA) method became popular in body composition analysis (BCA) in rece…
-
OpenAlex 81.7%
Electrical impedance tomography (EIT) produces cross-sectional images of the electrical resistivity distribution within the body, made from voltage or current measurements through electrodes attached around the body. The authors describe a gated EIT system to image the cardiogenic electrical resistivity variations and…
-
OpenAlex 80.5%
Özet henüz yok.
-
SJR Q1
JCR Q3
OpenAlex üst %10
OpenAlex 92.1%
This paper proposes an algorithm for detecting current transformer (CT) saturation by analyzing a secondary current. The current has points of inflection where saturation begins and ends. Then, discontinuity in the first difference of the current arises at the next instants of points of inflection, where the second an…
-
YÖKSİS
SJR Q1
JCR Q1
OpenAlex 88.4%
The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i…
-
OpenAlex 87.7%
Özet henüz yok.
Akademisyenler
10 akademisyen
- BEHÇET MURAT EYÜBOĞLU 65 yazar konusu
- NEVZAT GÜNERİ GENÇER 61 yazar konusu
- YEŞİM SERİNAĞAOĞLU DOĞRUSÖZ 17 yazar konusu
- EVREN DEĞİRMENCİ 15 yazar konusu
- CİHAN GÖKSU 14 yazar konusu
- AHMET SABUNCU 7 yazar konusu
- MUSTAFA TEK 7 yazar konusu
- MURAT TÜMER 5 yazar konusu
- GÖKHAN ŞENGÜL 4 yazar konusu
- NİHAT ÇANKAYA 2 yazar konusu