İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2025 · article

Simultaneous Determination of Nickel(II), Copper(II), and Cobalt(II) at Trace Levels Using Schiff Base Complexes by Reversed-Phase High-Performance Liquid Chromatography in Environmental Samples

ISSN1061-9348
YÖKSİS OpenAlex
Yıl2025
Atıf3OpenAlex
Yüzdelik%74,3
FWCI1,131,00 = dünya ortalaması
Scopus (SJR)Q3
WoS (JCR)Q4

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of Analytical Chemistry
  • Katalog eşleşmesi (ISSN)Journal of Analytical Chemistry
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Abstract A new method for the simultaneous determination of Ni(II), Cu(II), and Co(II) ions in environmental samples by reversed-phase liquid chromatography was developed. The developed method is based on the synthesis of the quadrivalent Schiff base 6,6'-((1E,1'E)-(ethane-1,2-diylbis(azaneylylidene))bis(methaneylylidene))bis(3-methoxyphenol) by the condensation reaction between 2-hydroxy-4-methoxybenzaldehyde and ethylenediamine. The resulting Schiff base was used as a chelating agent to convert the targeted ions into metal-ligand complexes within 1 min, which were extracted on an octadecylsilane (ODS) solid-phase extraction mini-column and then injected into a reversed-phase high-performance liquid chromatography system. Sufficient separation of the metal-ligand complexes was achieved on a GL Sciences Intersil ODS-3 column with a mobile phase composition of methanol-acetonitrile-water (30 : 30 : 40, v/v) within 6 min and detection by an ultraviolet detector at 254 nm. The limits of detection were found to be 0.45, 0.40, and 1.47 µg/L for Co2+, Cu2+, and Ni2+, respectively. Recoveries from water samples ranged from 97.4 to 103.6%, with relative standard deviation values between 0.4 and 1.7%. While the targeted metal ions were not detected in a sample from the remote upstream area of the Kabaca Stream (Artvin, Turkey), concentrations were found to be 116.4 µg/L for Cu2+ and 32.9 µg/L for Ni2+ in a sample taken from the Kabaca Stream near the industrial area (Artvin, Turkey). Co2+ was below the limit of detection in both cases. In addition, the developed method was also validated using the inductively coupled plasma optical emission spectrometry technique.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

3atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 1 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2026 A rapid and sustainable dispersive Micro-solid phase extraction method based on a novel Zn-NFoH sorbent for trace Lead(II) determination in food and water matricesAtıf 0 · OpenAlex

Yazarlar

2
  1. MUSTAFA UMUT KONANÇ 1
  2. ADEM ASAN ONDOKUZ MAYIS ÜNİVERSİTESİ 2