This paper presents a new control strategy based on Lyapunov-function and proportional-resonant (PR) controller for single-phase grid-connected LCL-filtered voltage-source inverters (VSIs). While Lyapunov-function-based control guarantees the global stability of the system, the PR controller is employed to process the grid current error and determine the inverter current reference. However, it is shown that the conventional Lyapunov-function-based control (CLFBC) together with the PR control cannot damp the inherent resonance of the LCL filter. Therefore, this control approach is modified by adding a capacitor voltage loop so as to achieve the desired resonance damping. In addition, a transfer function from the reference grid current to actual grid current is formulated in terms of the LCL-filter parameters and their possible variations in the proposed control strategy. An important consequence of using the PR controller is that the need for performing first and second derivative operations in the generation of inverter current reference is eliminated. Also, a zero steady-state error in the grid current is guaranteed in the case of variations in the LCL-filter parameters. The computer simulations and experimental results obtained from a 3.3-kW system show that the proposed control strategy exhibits a good performance in achieving the required control objectives such as fast dynamic response, zero steady-state error, global stability, and sinusoidal grid current with low total harmonic distortion (THD).
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
213atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 11 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2019 Sliding-Mode Control in Natural Frame With Reduced Number of Sensors for Three-Phase Grid-Tieditalic LCL/italic-Interfaced InvertersAtıf 101 · OpenAlex
- 2022 Model Predictive Control Strategy for Induction Motor Drive Using Lyapunov Stability ObjectiveAtıf 39 · OpenAlex
- 2022 Model Predictive Control Strategy for Induction Motor Drive Using Lyapunov Stability ObjectiveAtıf 39 · OpenAlex
- 2019 Power Control of Single Phase Active RectifierAtıf 8 · OpenAlex
- 2019 Power Control of Single Phase Active RectifierAtıf 8 · OpenAlex
- 2023 An Expanded Lyapunov-Function Based Control Strategy for Cascaded H-Bridge Multilevel Active Front-End ConvertersAtıf 5 · OpenAlex
- 2020 Pasif seri sönümleme direncinin LCL filtreli bir fazlı şebeke etkileşimli evirici üzerine etkisiAtıf 5 · OpenAlex
- 2026 Lyapunov Control Strategy for Full‐Bridge Inverter‐Based UPS Applications Using Load Current EstimatorAtıf 1 · OpenAlex
- 2025 Lyapunov Control Strategy for Full‐Bridge Inverter‐Based UPS Applications Using Load Current EstimatorAtıf 1 · OpenAlex
- 2020 BİR FAZLI DGM DOĞRULTUCU İÇİN LCL FİLTRE TASARIMI VE AKTİF GÜÇ KONTROLÜAtıf 0 · OpenAlex