İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2024

Biomechanical evaluation of implant options for unilateral maxillary defects: a finite element analysis

BMC ORAL HEALTH

YÖKSİS OpenAlex Açık erişim · gold SJR Q1 JCR Q1 Atıf 10 Üst %10 Yüzdelik 93.7% FWCI 3.76
Yıl
2024
ISSN
1472-6831
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

OBJECTIVE: This study aimed to evaluate stress distribution in unilateral maxillary defects using finite element analysis (FEA) to compare subperiosteal (SI) and zygomatic implants (ZI). MATERIALS AND METHODS: A 3D model of a unilaterally atrophied maxilla was reconstructed from CT scans. Five scenarios were simulated: (1) quad zygoma implants (SC1), (2) zygoma and conventional implants (SC2), (3) two-piece SI and conventional implants (SC3), (4) one-piece SI and conventional implants (SC4) and (5) one-piece SI implant (SC5). Mechanical properties were assigned based on data in the literature; a 450 N force for occlusal loading and a 93 N force for oblique loads were applied. RESULTS: Under vertical loading, SC2 exhibited the highest tensile stress (Pmax) in the atrophic region (R-AM), while SC4 showed the lowest Pmax across the entire maxilla, indicating better stress distribution. Under oblique forces, SC2 also showed the highest Pmax in R-AM, while SC5 had the lowest Pmax overall. Minimum principal stress (Pmin) followed similar patterns, with SC4 and SC5 demonstrating lower stress levels than the other scenarios. Abutment stresses were highest in SC2 and lowest in SC4. Overall, the SI scenarios (SC3-SC5) exhibited lower stress transmission to the alveolar bone than the ZI scenarios (SC1 and SC2), with SC4 providing the most balanced stress distribution across all regions. CONCLUSIONS: SI implants, mainly the one-piece SI (SC4), offered a more favourable stress distribution than ZI implants in unilateral maxillary defects, reducing the risk of excessive bone stress. This finding suggests that SI implants may be superior for such cases, although individual patient anatomy should guide implant selection. Further clinical studies are necessary to confirm these biomechanical findings in vivo. CLINICAL RELEVANCE: This study underscores the crucial role of implant selection in minimising stress on the alveolar bone in unilateral maxillary defects. Based on these findings, we recommend personalised implant strategies based on biomechanical insights to enhance outcomes in maxillofacial reconstruction.

Konular

  • Dental Implant Techniques and Outcomes
  • Bone Tissue Engineering Materials
  • Cleft Lip and Palate Research

Birincil konu Dental Implant Techniques and Outcomes

Yazarlar

  1. GÜLİN ACAR
  2. ILGIN ARI
  3. EMRE TOSUN HACETTEPE ÜNİVERSİTESİ