İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2009 · article

Investigation of Effects of Nonlinear Static Analysis Procedures to Performance Evaluation on Low-Rise RC Buildings

YÖKSİS OpenAlex
Yıl2009
Atıf7OpenAlex
Yüzdelik%87,2
FWCI1,881,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of Performance of Constructed Facilities
  • Katalog eşleşmesi (ISSN)Journal of Performance of Constructed Facilities
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

The aim of the study is to compare and evaluate structural response demands obtained from nonlinear static analysis procedures (NSPs) which are displacement coefficient method (DCM) recommended in FEMA 356 and capacity spectrum method (CSM) recommended in ATC 40. For these reasons, three of three-dimensional low-rise RC buildings with different characteristics are investigated. In order to determine nonlinear behavior of the buildings under lateral loads, the base shear-roof displacement relationships (capacity curves) are obtained by pushover analysis including P-delta effects. Then by considering four different seismic hazard levels, building performances are determined by using the CSM and by using from DCM results determined in a previous study. In order to determine performance levels of the buildings, maximum beam and column plastic rotation demands and maximum story drift demands are determined in the related maximum displacement demands. Plastic strains in the equivalent diagonal struts, representing the nonstructural infill walls, are also determined, similarly. Comparing structural response quantities (such as plastic rotations, story drifts, etc.) obtained from the NSPs for considered low-rise RC buildings, effects of different NSPs in performance evaluations of the buildings are investigated comparatively, as well.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

7atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2015 Load carrying system characteristics of existing Turkish RC building stockAtıf 23 · OpenAlex
  2. 2023 Effects of Frame Discontinuity on Seismic Behaviour of RC BuildingsAtıf 5 · OpenAlex

Yazarlar

2
  1. Erdal İrtem 1
  2. UMUT HASGÜL BALIKESİR ÜNİVERSİTESİ 2