Thermodynamic and environmental assessment of integrating a heat-pump tumble dryer with a PEM electrolyzer

YÖKSİS OpenAlex
Yıl2026
Atıf0OpenAlex
Yüzdelik%21,7
FWCI0,01,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS
  • Katalog eşleşmesi (ISSN)Energy Sources, Part A: Recovery, Utilization and Environmental Effects
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Hydrogen is increasingly regarded as an energy carrier for electrification and long-duration storage. This study presents a combined modeling and experimentally validated thermodynamic analysis of a household-scale hydrogen production concept integrating a heat-pump tumble dryer with a proton exchange membrane electrolyzer (PEME). The work combines steady-state thermodynamic and exergy modeling, experimental validation using air-side measurements, and a scenario-based life cycle assessment (LCA). A thermodynamic model of the integrated system was developed in engineering equation solver (EES), and a parametric analysis examined ambient temperature, relative humidity, tumble-air temperature, and alternative working fluids. Key metrics include coefficient of performance (COP), exergy destruction, condensate production, and hydrogen yield. Under baseline conditions, the system achieves COP = 4.90, produces 5.546 kg condensate/cycle, and yields 0.5453 kg H₂/cycle. Increasing ambient temperature (15–40 °C) raises COP by up to 14% and lowers exergy destruction (0.1999 → 0.1775 kW). Raising tumble-air temperature (65–75 °C) increases COP (3.033 → 5.406), reduces exergy destruction by 29%, and increases hydrogen output threefold. Exergy losses are dominated by the expansion valve (45%) and the condenser (39%). Among refrigerants, R600a and R1270 provide the highest gains in condensate and hydrogen production. A use-phase Life-cycle assessment (LCA) shows per-cycle Global Warming Potential (GWP) is reduced for condensate reuse (0.4087 → 0.4070 kg CO₂-eq/cycle). Overall, results suggest that dryer-condensate-fed electrolysis is technically feasible and offers thermodynamic and climate-impact benefits at the household scale.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

0atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yazarlar

4
  1. ANIL ERDOĞAN 1
  2. Aziz Başdemir 2
  3. Burcu Tosun 3
  4. YAĞMUR NALBANT ATAK ATILIM ÜNİVERSİTESİ 4