Makale detayı · 2025 · article
Evaluation of the fabrication trueness and internal fit of additively manufactured two-piece zirconia abutments with different build orientations compared to subtractively manufactured abutments
Veri kaynağı ayrımı
- YÖKSİSYÖKSİS makale kaydı
- YÖKSİS dergi adıJournal of Dentistry
- Katalog eşleşmesi (ISSN)Journal of Dentistry
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
OBJECTIVE: To evaluate the effect of build orientation on the fabrication trueness and fit of additively manufactured 2-piece zirconia abutments when compared with those manufactured subtractively in 3 mol% and 4 mol% yttria-stabilized zirconia (3Y-TZP and 4Y-TZP). METHODS: A titanium-base (Ti-base) abutment was digitized with a scan body and an industrial scanner to design a 2-piece zirconia abutment with a 50 µm cement gap. This design was used to manufacture zirconia abutments additively in different orientations (0-degree, AM-0; 15-degree, AM-15; 30-degree, AM-30; 45-degree, AM-45; 180-degree, AM-180) and subtractively from 3Y-TZP and 4Y-TZP (SM-3 and SM-4) (n=5). An intraoral scanner was used to digitize all abutments, when they were seated on the Ti-base, and only the Ti-base. Abutments' trueness (overall, external, intaglio, and marginal) was analyzed with the root mean square (RMS) method, and their fit was assessed with the triple-scan protocol. Data were analyzed with 1-way analysis of variance and Tamhane's T2 tests (α = 0.05). RESULTS: SM-3 abutments had the lowest overall and external RMS (P ≤ 0.023). SM-3 and SM-4 abutments mostly had lower intaglio and AM-0 abutments mostly had lower gingival RMS (P ≤ 0.013). Except for AM-0 and SM-3 (P ≥ 0.930), SM-4 abutments had the lowest average gaps (P ≤ 0.041). CONCLUSIONS: SM-3 abutments mostly had higher fabrication trueness, while AM-0 abutments had trueness similar to or higher than the other additively manufactured abutments. AM-0, SM-3, and SM-4 abutments had similar fit with average gaps lower than 50 µm.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
8atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 9 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2025 Flexural and structural behavior of additively manufactured zirconia: Influence of firing process and build orientationAtıf 3 · OpenAlex
- 2026 Influence of manufacturing protocol, polishing, and thermocycling on water contact angle and hardness of zirconia: Comparison of additive and subtractive techniquesAtıf 0 · OpenAlex
- 2026 Load-bearing capacity of screw-retained zirconia crown-abutment complexes of different heights fabricated by additive and subtractive methods after cyclic loading: An in vitro studyAtıf 0 · OpenAlex
- 2026 Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prosthesesAtıf 0 · OpenAlex
- 2026 The effect of toothpaste and thermal aging on extrinsically stained additively manufactured zirconia: A comparative study on surface roughness and stain durabilityAtıf 0 · OpenAlex
- 2026 The effect of toothpaste and thermal aging on extrinsically stained additively manufactured zirconia: A comparative study on surface roughness and stain durabilityAtıf 0 · OpenAlex
- 2026 Load-bearing capacity of screw-retained zirconia crown-abutment complexes of different heights fabricated by additive and subtractive methods after cyclic loading: An in vitro studyAtıf 0 · OpenAlex
- 2026 Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prosthesesAtıf 0 · OpenAlex
- 2026 How the Build Angle Affects the Marginal and Internal Fit of 3D Printed Definitive FPDs : An in Vitro StudyAtıf 0 · OpenAlex