İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2022 · article

The round femoral stem provides a similar clinical outcome but more serious proximal stress shielding compared to the rectangular stem in cementless total hip arthroplasty without a shortening osteotomy in patients with Crowe type 2 or 3 hip dysplasia

Dergi Joint Diseases and Related Surgery
ISSN2687-4784
YÖKSİS OpenAlex Açık erişim · diamond TR Index
Yıl2022
Atıf1OpenAlex
Yüzdelik%50,6
FWCI0,211,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJoint Diseases and Related Surgery
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

OBJECTIVES: This study aims to compare clinical and radiological follow-up results of a rectangular (SL-Plus®) or a round (Synergy®) femoral component in patients with Crowe type 2 or 3 hip dysplasia operated with total hip arthroplasty (THA) without a shortening osteotomy. PATIENTS AND METHODS: Between January 2012 and December 2017, a total of 34 hips of 30 female patients (mean age: 42.9±11.6 years; range, 24 to 66 years) were retrospectively analyzed. All patients were evaluated using the Harris Hip Score (HHS) and Visual Analog Scale (VAS) for pain pre- and postoperatively. Intra- and postoperative complications were noted. Evaluation criteria included leg length discrepancy, stem subsidence, bone atrophy or hypertrophy around the stem according to Gruen zones, operative time, and intraoperative blood loss. Correlation analysis of radiological, clinical findings, and stem size was performed. RESULTS: The mean follow-up was 61.3±27.2 months. The mean postoperative HHS was 89.3±6.2 vs. 93.1±9.1, and the mean VAS score 1±0.6 vs. 1±0.8 in round and rectangular stem groups at the final follow-up. No significant differences were detected between the groups in any of the evaluated parameters, except for a more severe degree of stress shielding observed in the round stem group. Round stem size was positively correlated with a more severe stress shielding (r=0.55, p=0.020). No patient had to be revised during the follow-up period. The overall complication rate was 9%. CONCLUSION: Successful and comparable results can be obtained with cementless THA in patients with high riding dysplastic hips implanting either of the femoral components, a rectangular or a round stem. Although the round stem was associated with more common proximal stress shielding, this was not associated with worse clinical outcomes.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

1atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2024 Rectangular femoral stems can successfully accommodate the medullary canal in patients with severe hip dysplasia operated on with total hip arthroplasty and a shortening osteotomy: A morphometric studyAtıf 1 · OpenAlex
  2. 2024 Rectangular femoral stems can successfully accommodate the medullary canal in patients with severe hip dysplasia operated on with total hip arthroplasty and a shortening osteotomy: A morphometric studyAtıf 1 · OpenAlex

Yazarlar

3
  1. MAHMUT ENES KAYAALP 1
  2. FAHRİ ERDOĞAN 2
  3. GÖKHAN KAYNAK İSTANBUL ÜNİVERSİTESİ-CERRAHPAŞA 3