Female Breast Radiation Exposure During Thorax Multidetector Computed Tomography and the Effectiveness of Bismuth Breast Shield to Reduce Breast Radiation Dose
Dergi
Journal of Computer Assisted Tomography- Yıl
- 2007
- Tür
- article
Veri kaynağı ayrımı
- YÖKSİS dergi adı Journal of Computer Assisted Tomography
- OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)
Özet
OpenAlex · İngilizce
OBJECTIVE: The purpose of our study was to determine the breast radiation dose when performing routine thoracic multidetector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth breast shield when performing thoracic MDCT. MATERIAL AND METHODS: The dose reduction achievable by shielding the adult (18 years or older) female breasts was studied in 50 women who underwent routine thoracic MDCT. All examinations were performed with a 16-MDCT scanner (Sensation Cardiac 16; Siemens Medical Solutions). To compare the shielded/unshielded breast dose, the examination was performed with (right breast) and without (left breast) breast shielding in all patients. With this technique, the superficial breast doses were calculated. To determine the average glandular breast radiation dose, we imaged an anthropomorphic dosimetric phantom into which calibrated dosimeters were placed to measure the dose to breast. The phantom was imaged using the same protocol. Radiation doses to the breasts with and without the breast shielding were measured and compared using the Student t test. RESULTS: In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded lung. The mean radiation doses to the breasts with the shield and to those without the shield were 8.6 +/- 2.33 versus 14.46 +/- 3.94 mGy, respectively. The breast shield enabled a 40.53% decrease in radiation dose to the breast. The difference between the dose received by the breasts with and that received by the breasts without bismuth shielding was significant, with a P value of less than 0.001. CONCLUSIONS: Bismuth in-plane shielding for routine thoracic MDCT decreased radiation dose to the breast without qualitative changes in image quality. The other radiosensitive superficial organs (eg, testes and thyroid gland) specifically must be protected with shielding.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
81 atıf
OpenAlex cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 4 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- The effect of current environmental risk factors on breast cancer 2013
- Güncel Çevresel Risk Faktörlerinin Meme Kanserine Etkisi 2013
- Chest Circumference as a Predictive Parameter of Computed Tomography Coronary Angiography Radiation Doses from Dual Source Computed Tomography 2013
- Chest Circumference as a Predictive Parameter of Computed Tomography Coronary Angiography Radiation Doses from Dual-Source Computed Tomography 2013