İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2016

Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients withde novocoronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial

Dergi

European Heart Journal
OpenAlex Açık erişim · hybrid SJR Q1 JCR Q1 Atıf 187 Üst %1 Yüzdelik 99.8% FWCI 28.4
Yıl
2016
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS dergi adı European Heart Journal
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex · İngilizce

AIMS: Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. METHODS AND RESULTS: The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. CONCLUSION: The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. CLINICALTRIALSGOV IDENTIFIER: NCT01960504.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

187 atıf

OpenAlex cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 7 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. In vivo serial invasive imaging of the second-generation drug-eluting absorbable metal scaffold (Magmaris — DREAMS 2G) in de novo coronary lesions: Insights from the BIOSOLVE-II First-In-Man Trial 2017 Atıf 75 · OpenAlex
  2. Safety and clinical performance of a drug eluting absorbable metal scaffold in the treatment of subjects with de novo lesions in native coronary arteries: Pooled 12‐month outcomes of BIOSOLVE‐II and BIOSOLVE‐III 2018 Atıf 64 · OpenAlex
  3. Sustained Safety and Performance of the Second-Generation Sirolimus-Eluting Absorbable Metal Scaffold: Pooled Outcomes of the BIOSOLVE-II and -III Trials at 3 Years 2020 Atıf 37 · OpenAlex
  4. Comparison of clinical outcomes between Magmaris and Orsiro drug eluting stent at 12 months: Pooled patient level analysis from BIOSOLVE II–III and BIOFLOW II trials 2019 Atıf 32 · OpenAlex
  5. Impact of procedural characteristics on coronary vessel wall healing following implantation of second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary artery lesions: an optical coherence tomography analysis 2018 Atıf 15 · OpenAlex
  6. First Report of Edge Vascular Response at 12 Months of Magmaris, A Second-Generation Drug-Eluting Resorbable Magnesium Scaffold, Assessed by Grayscale Intravascular Ultrasound, Virtual Histology, and Optical Coherence Tomography. A Biosolve-II Trial Sub-Study 2019 Atıf 12 · OpenAlex
  7. Serial 3-Dimensional Optical Coherence Tomography Assessment of Jailed Side-Branch by Second-Generation Drug-Eluting Absorbable Metal Scaffold (from the BIOSOLVE-II Trial) 2019 Atıf 2 · OpenAlex

Yazarlar

Yazar bilgisi yok.