Exergy analysis of an inter city bus air conditioning system

International Journal of Exergy

YÖKSİS OpenAlex SJR Q2 JCR Q4 Atıf 14 Yüzdelik 82.7% FWCI 1.56
Yıl
2016
ISSN
1742-8297
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

In this paper, exergy analysis was implemented to improve the inter-city bus air-conditioning (AC) system design. Firstly, an inter-city bus with a passenger capacity of 56 people was selected and then its hourly cooling load capacity was determined with the help of cooling load hourly analysis program (HAP). Analyses were performed for different air mixing ratios (MRs) and seasons. Coefficient of performance (COP), exergy efficiency (ψ) and exergy destructions (Ėxdest) of whole system and its each sub-units were evaluated. Results demonstrated that the atmospheric air temperature and air MR substantially affect the inter-city bus AC systems' performance. According to the results obtained for July, when air MR is 0.5, maximum exergy destruction value was calculated as 6.96 kW at compressor. Exergy destruction values were computed as 2.78, 2.61 and 0.99 kW for evaporator, condenser and expansion valve, respectively.

Konular

  • Refrigeration and Air Conditioning Technologies
  • Maritime Transport Emissions and Efficiency
  • Thermodynamic and Exergetic Analyses of Power and Cooling Systems

Birincil konu Refrigeration and Air Conditioning Technologies

Yazarlar

  1. ERDİ TOSUN
  2. MEHMET BİLGİLİ
  3. GÖKHAN TÜCCAR ADANA ALPARSLAN TÜRKEŞ BİLİM VE TEKNOLOJİ ÜNİVERSİTESİ
  4. ABDULKADİR YAŞAR ÇUKUROVA ÜNİVERSİTESİ
  5. KADİR AYDIN