Makale detayı · 2016 · conference-abstract
Abstract PR535
Veri kaynağı ayrımı
- YÖKSİS dergi adıAnesthesia & Analgesia
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
Background & Objectives: The aim of this study was to compare the ease of intubation entry and the glottic view provided by Macintosh Laryngoscope, TruView EVO2 and McGrath Videolaryngoscopy in the management of the paediatric airway. Materials & Methods: The study included 90 paediatric cases aged 4-10 years who were to undergo endotracheal intubation for surgery. The cases were randomly allocated to 3 groups for the type of intubation to be applied; Group 1 (n=30) Macintosh Laryngoscope, Group 2 (n=30) TruView EVO 2 and Group 3 (n=30) McGrath videolaryngoscope. The laryngosccopy, intubations were performed by an anaesthesiologist with >5 years experience of intubations. Before this study, the operators had performed 20 intubations each with the TruView EVO 2 and McGrath videolaryngoscope. The demographic data of the patients, the Mallampati and Cormack Lehane scores, EtCO2, SpO2 and haemodynamic values were recorded. The time of intubation (the time from the laryngoscope entering the mouth until the tube is seen to have passed the vocal cords), how many attempts were made for intubation, the percentage of glottic opening (POGO) seen with the laryngoscope and the Intubation Difficulty Scale (IDS) scores were recorded. If intubation could not be made in 3 attempts or took more than 180 seconds, it was accepted as failed intubation. Results: In the Macintosh group, the EtCo2 values at 3 and 5 minutes after intubation were found to be statistically significantly low. The Mallampati and Cormack Lehane scores were similar in all the groups. The POGO scores in the Macintosh group were statistically significantly low (p<0.05). The IDS scores in the TruView group were statistically significantly high (p<0.05). The time of intubation was found to be statistically significantly shorter in the McGrath videolaryngoscopy group (p<0.05). The number of attempts for intubation was similar in all 3 groups. Conclusion: The results of this study showed that the POGO scores in the Macintosh laryngoscopy group were lower than those of the other two groups. There was felt to be a need for external laryngeal pressure at a higher rate in the TruView EVO2 group. Although better visualisation of the orpharyngeal, glottic structures was obtained with videolaryngoscopy methods, they did not sufficiently facilitate intubation as they are indirect methods and there was a lack of experience. References: 1. Inal MT, Memis D, Kargi M, Oktay Z, Sut N. Comparison of TruView EVO2 with Miller laryngoscope in paediatric patients. Eur J Anaesthesiol 2010;27:950–954 2. Arora S, Sayeed H, Bhardwaj N: Comparison of Truview EVO2 laryngoscope with macintosh laryngoscope. Saudi JAnaesh 2013;7:244-248 Disclosure of Interest: None declared
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
2atıfOpenAlex · cited_by_count (önbellek / veritabanı)