The effects of soft-start vs continuous-light polymerization on microleakage in Class II resin composite restorations.

Dergi PubMed
OpenAlex
Yıl2005
Atıf15OpenAlex
Yüzdelik%73,7
FWCI1,351,00 = dünya ortalaması

Veri kaynağı ayrımı

  • YÖKSİS dergi adıPubMed
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex İngilizce

PURPOSE: Despite the different light sources and polymerization techniques developed to eliminate it, microleakage of resin composite still remains a problem. This in vitro study was designed to compare the effects of exponential mode soft-start polymerization with those of standard and high-intensity continuous light polymerization on microleakage in Class II resin composite restorations. MATERIALS AND METHODS: Standardized Class II cavities (4 mm wide, 4 mm long, 5 to 6 mm high, 2 mm deep) were prepared in 50 extracted human molars. Specimens were divided into 5 groups (n = 10) and restored using the same hybrid resin composite (Z250), but separately polymerized by one of five different methods: group 1: continuous halogen light polymerization for 40 s; group 2: continuous high-intensity halogen light polymerization for 10 s; group 3: exponential mode soft-start halogen light polymerization for a total of 40 s; group 4: continuous LED light polymerization for 40 s; Group 5: exponential mode soft-start LED light polymerization for a total of 40 s. All specimens were thermocycled for 1000 cycles at 5 degrees C to 55 degrees C and then placed in 0.5% basic fuchsin dye for 24 h. Specimens were then rinsed, embedded in resin and sectioned longitudinally. Dye penetration at occlusal and cervical margins was rated using a scale of 0 to 4. Data was analyzed using Kruskal-Wallis and Mann-Whitney U-tests. RESULTS: Significantly lower marginal leakage was recorded with exponential mode soft-start polymerization when compared to continuous light polymerization. No significant differences in microleakage were observed between LED and halogen light polymerization. CONCLUSION: Within the limits of this in vitro study, the use of the soft-start exponential mode of LED and/or halogen light units in the polymerization of hybrid composite was found to produce significantly lower microleakage at both occlusal and cervical margins when compared to continuous light polymerization methods.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

15atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 5 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2008 Temperature rise and shear bond strength of bondable buccal tubes bonded by various light sourcesAtıf 20 · OpenAlex
  2. 2008 Temperature rise and shear bond strength of bondable buccal tubes bonded by various light sourcesAtıf 20 · OpenAlex
  3. 2008 The Effect of Different Light Sources on Microleakage of Bleached EnamelAtıf 6 · OpenAlex
  4. 2021 The Effects of Thermo-mechanical Aging on Microleakage in Composite Restorations Polymerized Using One New Generation and Two Conventional Led Light Curing UnitsAtıf 0 · OpenAlex
  5. 2021 The Effects of Thermo-mechanical Aging on Microleakage in Composite Restorations Polymerized Using One New Generation and Two Conventional Led Light Curing UnitsAtıf 0 · OpenAlex

Yazarlar

1
  1. ADİL NALÇACI ANKARA ÜNİVERSİTESİ 1