Makale detayı · 2007
Collaborative studies to establish the first World Health Organization International Standard for detection of human antibody against human platelet antigen‐3a
Dergi
Vox Sanguinis- Yıl
- 2007
- Tür
- article
Veri kaynağı ayrımı
- YÖKSİS dergi adı Vox Sanguinis
- OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)
Özet
OpenAlex · İngilizce
BACKGROUND AND OBJECTIVES: The platelet-specific antibody anti-human platelet antigen-3a (anti-HPA-3a) is involved in neonatal alloimmune thrombocytopenia, post-transfusion purpura, and platelet refractoriness. However, HPA-3a antibodies are often difficult to detect, probably because the antigen is labile. This report describes the production of a freeze-dried preparation of pooled human plasma, coded 03/190, containing IgG antibodies against the HPA-3a. The material is intended for use as a minimum sensitivity reagent in glycoprotein-specific assays currently used for anti-HPA-3a detection. Laboratories can use it to assess the sensitivity of their 'in-house' assays for anti-HPA-3a and to calibrate local controls for routine use in each batch of tests. MATERIALS AND METHODS: Plasma containing anti-HPA-3a was obtained from a mother of two babies both born with severe thrombocytopenia, and following dilution it was freeze dried in glass ampoules. RESULTS: Two collaborative studies demonstrated that the candidate material contained anti-HPA-3a and human leucocyte antigen (HLA) class I antibodies, but no other HPA antibodies that might confuse the detection of the anti-HPA-3a. The minimum dilution that should give a positive result was determined to be 1 : 8 by two further international collaborative studies involving a total of 49 laboratories in 23 countries. CONCLUSION: The material also contains HLA antibodies and is suitable for use only in techniques that are glycoprotein specific (i.e. monoclonal antibody immobilization of platelet antigens and enzyme-linked immunosorbent assay) where only HPA antibodies will be detected. This standard will allow laboratories to measure their sensitivity of detection of anti-HPA-3a and will also allow those laboratories with relatively insensitive techniques to monitor their performance as they improve their methodology.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
12 atıf
OpenAlex cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 5 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- Interlaboratory variation in the detection of HPA‐specific alloantibodies and in molecular HPA typing 2007
- Infection materno-fœtale à chikungunya associée à un syndrome de Bernard-Soulier 2011
- An International Reference Reagent (minimum sensitivity) for the detection of anti‐human platelet antigen 1a 2008
- Advances in alloimmune thrombocytopenia laboratory investigations 2009
- International Society of Blood Transfusion: The Platelet Immunobiology Working Party 2008