İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2024 · article

Comparative evaluation of the accuracy of electronic apex locators and cone-beam computed tomography in detection of root canal perforation and working length during endodontic retreatment

ISSN1472-6831
YÖKSİS OpenAlex Açık erişim · gold
Yıl2024
Atıf5OpenAlex
Yüzdelik%84,7
FWCI1,861,00 = dünya ortalaması
Scopus (SJR)Q1
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıBMC Oral Health
  • Katalog eşleşmesi (ISSN)BMC Oral Health
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

BACKGROUND: To evaluate the accuracy of the electronic apex locators (EALs), and Cone-Beam Computed Tomography (CBCT) scanning, both in working length (WL) determination and in the detection of root canal perforations in retreatment cases. METHODS: Sixty human mandibular premolars were selected. After crown removal partially and canal access, root canals were instrumented and irrigated. The obturation process utilized gutta-percha and sealer with warm vertical compaction. Two groups were distinguished: one without perforation (Group 1) and the other with an apical third perforation (Group 2). Retreatment included filling removal, apical preparation, and irrigation. Actual working lengths (AWL) were determined using a stereomicroscope. CBCT images were used to measure CBCT working length (CWL), with adjustments for optimal views. Propex II and Dentaport ZX were used to measure electronic working length (EWL). Differences between EWL and AWL, as well as CWL, were analyzed to gauge accuracy. Data underwent Two-way ANOVA analysis. Measurements within ± 0.5 and ± 1 mm tolerance ranges were deemed successful for each device, followed by applying the Pearson Chi-square test. RESULTS: The study reveals no significant inter-group variations in device performance (p > .05). Dentaport ZX missed detecting perforation in two Group 2 (apical perforation) cases. For ± 1 mm tolerance, Propex II displayed the highest success in Group 2 (apical perforation). CONCLUSION: This study demonstrates the comparable performance of Propex II, Dentaport ZX, and CBCT in endodontic retreatment, providing insights into diagnostic reliability.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

5atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 5 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2025 Comparative accuracy of cone-beam computed tomography and ıntegrated electronic apex locator in apically resected teeth: an ex vivo studyAtıf 1 · OpenAlex
  2. 2025 Comparative accuracy of cone‑beam computed tomography and ıntegrated electronic apex locator in apically resected teeth: an ex vivo studyAtıf 1 · OpenAlex
  3. 2025 Accuracy of two electronic apex locators in mandibular mesial canals and the influence of root canal anatomy: a micro CT-based studyAtıf 1 · OpenAlex
  4. 2025 Accuracy of two electronic apex locators in mandibular mesial canals and the influence of root canal anatomy: a micro-CT-based studyAtıf 1 · OpenAlex
  5. 2025 Comparative accuracy of cone-beam computed tomography and ıntegrated electronic apex locator in apically resected teeth: an ex vivo study.Atıf 1 · OpenAlex

Yazarlar

3
  1. SİMAY KOÇ DEVECİ 1
  2. HATİCE HARORLI AKDENİZ ÜNİVERSİTESİ 2
  3. ALPER KUŞTARCI 3