İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2023 · article

Comparison of Clinical Outcomes and Patient Satisfaction Between Two Different Diffractive Trifocal IntraocularLenses Implantation: Prospective Clinical Trial

Dergi Turkiye Klinikleri Oftalmoloji dergisi
ISSN2146-9008
YÖKSİS OpenAlex Açık erişim · diamond TR Index
Yıl2023
Atıf0OpenAlex
Yüzdelik%21,7
FWCI0,01,00 = dünya ortalaması

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıTurkiye Klinikleri Oftalmoloji dergisi
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Objective: To compare the clinical outcomes and visual quality of subjects undergoing cataract surgery with the implantation of two different models of diffractive trifocal intraocular lenses (IOL). Material and Methods: This was a prospective, parallel-group, randomized, comparative, single-masked clinical study. A total of 30 subjects, who were scheduled to undergo bilateral cataract surgery were randomly assigned to two groups: RayOne and PanOptix IOL. The outcome measures were corrected and uncorrected distance visual acuity (CDVA, UDVA) at 4 m, uncorrected intermediate visual acuity (UIVA) at 80 and 60 cm, distance-corrected intermediate visual acuity (DCIVA) at 60 and 80 cm, distance-corrected and uncorrected near visual acuity at 40 cm, and patients' satisfaction. Results: Each group comprised 30 eyes of 15 subjects. No statistically significant differences were determined between the groups in terms of CDVA, UDVA, distance-corrected near visual acuity, and uncorrected near visual acuity. The monocular UIVA values at 80 cm were 0.09±0.09 logMAR in the RayOne IOL group and 0.19±0.11 logMAR in the PanOptix IOL group (p=0.01). The UIVA values at 60 cm were better in the PanOptix IOL group (p=0.049,p=0.01, respectively), and the DCIVA at 80 cm were better in the RayOne IOL group (p=0.01,0.047, respectively). The RayOne IOL group had more bothersome halos and starbursts (p=0.026,p=0.01, respectively). Conclusion: Both IOLs provided a very good restoration of visual acuity. However, with the PanOptix IOL, the likelihood of subjects experiencing bothersome halos and starbursts was less. The RayOne IOL might be a better choice for subjects that require further intermediate vision.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

0atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yazarlar

2
  1. ASLI ÇETİNKAYA YAPRAK AKDENİZ ÜNİVERSİTESİ 1
  2. MUSTAFA ÜNAL 2