İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2018

Evaluation of atrial electromechanical functions in dipper and nondipper hypertension patients using left atrial strain P-wave dispersion and P terminal force

ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES

YÖKSİS OpenAlex ISSN 0742-2822 DOI 10.1111/echo.14041 Atıf 12 SJR Q2 · 2017 JCR Q4

10.1111/echo.14041

YÖKSİS YÖKSİS makale kaydı

OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex kaydı

İngilizce (OpenAlex)

OBJECTIVE: Nondippers are known to carry a high risk of cardiovascular morbidity and mortality. The aim of this study was to investigate the effects of dipper and nondipper status of hypertension on left atrial (LA) systolic and diastolic functions using two-dimensional speckle tracking echocardiography (2D-STE), P-wave dispersion (PWD), and P terminal force (PTF) in hypertensive patients. METHODS: A total of 72 patients and 39 healthy individuals were included in the study. The patients were classified as nondippers if their daytime ambulatory systolic and diastolic blood pressure did not decrease by at least 10% during the night. Atrial electromechanical delay times, LA strain values were obtained by 2D-STE with automated software and compared between the groups. PWD and PTF data were calculated on the electrocardiography. RESULTS: Inter-atrial (dippers: 25.5 ± 3.9, nondippers: 32.2 ± 7.4, P < .001), left-atrial (dippers: 14.9 ± 3.7, nondippers: 18.2 ± 6.0, P = .016), and right atrial (dippers: 10.5 ± 2.1, nondippers: 14.2 ± 5.2, P < .001) electromechanical delay times were significantly longer in nondippers. LA strain S (dippers: 34.2 [29.7-38.7], nondippers: 27.7 [22.7-32.2], P < .001), LA strain E (dippers: 18.2 [16.6-20.1], nondippers: 14.4 [11.6-16.8], P < .001), and LA strain A (dippers: 15.8 [13.5-17.9], nondippers: 12.7 [9.9-14.5], P < .001) were significantly lower in nondippers. Nondippers also had an increased values of maximum P-wave duration (dippers: 0.117 [0.10-0.12], nondippers: 0.126 [0.12-0.14], P < .001), PWD (dippers: 0.062 [0.06-0.07], nondippers: 0.069 [0.06-0.08], P = .004), and PTF (dippers: 0.055 ± 0.02, nondippers: 0.066 ± 0.02, P = .02). CONCLUSION: Nondipping pattern in hypertensive patients had a worse cardiac remodeling, and impaired mechanical LA function compared with dipping pattern. The PWD and PTF findings support these changes.

OpenAlex zenginleştirmesi

Konular

  • Cardiovascular Function and Risk Factors
  • Atrial Fibrillation Management and Outcomes
  • Cardiac electrophysiology and arrhythmias

Tür: article Cardiovascular Function and Risk Factors

İndeks bilgisi

WoS (JCR) ve Scopus (SJR) çeyrekleri ISSN ve yayın yılına göre. · 2018

Scopus (SJR) / WoS (JCR)

Echocardiography

Scopus (SJR) Q2 0,57 En yakın yıl: 2017

Makale yılı 2018; gösterilen indeks yılı 2017.

WoS (JCR) Q4 JIF 1,3 2018 yılı

Üniversiteler

  • AKDENİZ ÜNİVERSİTESİ

Yazarlar

  1. Veysel Tosun
  2. Necmettin Korucuk
  3. Ali Yasar Kilinc
  4. Turgut Uygun
  5. Refik Emre Altekin
  6. Unal Guntekin
  7. Cengiz Ermis
  8. ÜNAL GÜNTEKİN AKDENİZ ÜNİVERSİTESİ