İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2014 · article

Accuracy of CBCT images in the assessment of buccal marginal alveolar peri-implant defects: effect of field of view

ISSN0250-832X
YÖKSİS OpenAlex Açık erişim · green Üst %1
Yıl2014
Atıf97OpenAlex
Atıf78Semantic Scholar · 4 etkili
Yüzdelik%99,1
FWCI9,61,00 = dünya ortalaması
Scopus (SJR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıDentomaxillofacial Radiology
  • Katalog eşleşmesi (ISSN)Dentomaxillofacial Radiology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

OBJECTIVES: To investigate the reliability and accuracy of cone beam CT (CBCT) images obtained at different fields of view in detecting and quantifying simulated buccal marginal alveolar peri-implant defects. METHODS: Simulated buccal defects were prepared in 69 implants inserted into cadaver mandibles. CBCT images at three different fields of view were acquired: 40 × 40, 60 × 60 and 100 × 100 mm. The presence or absence of defects was assessed on three sets of images using a five-point scale by three observers. Observers also measured the depth, width and volume of defects on CBCT images, which were compared with physical measurements. The kappa value was calculated to assess intra- and interobserver agreement. Six-way repeated analysis of variance was used to evaluate treatment effects on the diagnosis. Pairwise comparisons of median true-positive and true-negative rates were calculated by the χ² test. Pearson's correlation coefficient was used to determine the relationship between measurements. Significance level was set as p < 0.05. RESULTS: All observers had excellent intra-observer agreement. Defect status (p < 0.001) and defect size (p < 0.001) factors were statistically significant. Pairwise interactions were found between defect status and defect size (p = 0.001). No differences between median true-positive or true-negative values were found between CBCT field of views (p > 0.05). Significant correlations were found between physical and CBCT measurements (p < 0.001). CONCLUSIONS: All CBCT images performed similarly for the detection of simulated buccal marginal alveolar peri-implant defects. Depth, width and volume measurements of the defects from various CBCT images correlated highly with physical measurements.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

97atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 30 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2017 Age estimation based on pulp/tooth volume ratio measured on cone-beam CT imagesAtıf 116 · OpenAlex
  2. 2017 Endodontic Working Length Measurement Using Cone beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views Periapical Radiography and Apex Locator A Comparative Ex Vivo StudyAtıf 70 · OpenAlex
  3. 2017 Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo StudyAtıf 69 · OpenAlex
  4. 2015 Morphological and volumetric evaluation of the nasopalatinal canal in a Turkish population using cone beam computed tomographyAtıf 67 · OpenAlex
  5. 2017 Endodontic Working Length Measurement Using Cone beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views Periapical Radiography and Apex Locator A Comparative Ex Vivo StudyAtıf 56 · OpenAlex
  6. 2015 Morphological and volumetric evaluation of the nasopalatinal canal in a Turkish population using cone beam computed tomographyAtıf 54 · OpenAlex
  7. 2015 CBCT quantitative evaluation of mandibular lingual concavities in dental implant patientsAtıf 53 · OpenAlex
  8. 2015 CBCT quantitative evaluation of mandibular lingual concavities in dental implant patientsAtıf 48 · OpenAlex
  9. 2015 CBCT quantitative evaluation of mandibular lingual concavities in dental implant patientsAtıf 47 · OpenAlex
  10. 2015 CBCT quantitative evaluation of mandibular lingual concavities in dental implant patientsAtıf 47 · OpenAlex

Yazarlar

8
  1. KIVANÇ KAMBUROĞLU 1
  2. SEMA MURAT 2
  3. CENK KILIÇ 3
  4. SELCEN YÜKSEL ANKARA YILDIRIM BEYAZIT ÜNİVERSİTESİ 4
  5. H AVSEVER 5
  6. A FARMAN 6
  7. WC SCARFE 7
  8. İSMAİL HAKAN AVSEVER SAĞLIK BİLİMLERİ ÜNİVERSİTESİ 8