İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2024

Real time non-invasive monitoring of glucose and nitrogen sources with a novel window sliding based algorithm

Engineering Science and Technology, an International Journal

YÖKSİS OpenAlex Açık erişim · gold SJR Q1 JCR Q1 Atıf 2 Yüzdelik 45.5% FWCI 0.33
Yıl
2024
ISSN
2215-0986
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

The development of fast and cost-effective methods for measuring biological molecules has many advantages over conventional methods. However, these methods, which are used for monitoring biological molecules, have some drawbacks, such as high cost, time consumption, or labor intensity. On the other hand, microwaves are interacted with sample which can be calculated easily. Thus, microwaves provide compact, uncomplicated, non-invasive, and continuous monitoring of various critical substances such as glucose and nitrogen sources. Here, we show that a new algorithm, based on a sliding window approach, which effectively identifies the optimum operating point using Vector Network Analyzer (VNA) measurements of biological macromolecules including glucose, ammonium sulfate, and yeast extract. Moreover, the effect of container type (mica glass and urine container) on microwave sensing, using a VNA connected with a WR-28 adapter, was investigated. The experimental results confirmed that, mica glass resulted in better differentiation than urine container for glucose estimation. Furthermore, glucose, ammonium sulfate, and yeast extract amounts were effectively determined with novel algorithm. Reflection coefficients (S11) of glucose, yeast extract, and ammonium sulfate ranged between −14.14 dB, −14.41 dB, −10.65 dB, −10.85 dB, and −13.84 dB, −14.16 dB, respectively at optimal operation points when macromolecule concentrations were between 20–80 g/L. In addition, the time complexity of the proposed algorithm was performed and the overall time complexity is On (linear time) and the time complexity per incoming update is O1 (constant time). In this context, the algorithm is also suitable for online applications. The current study proposed a promising approach for cost effective and rapid estimation of biological substances.

Konular

  • Analytical Chemistry and Sensors
  • Electrochemical sensors and biosensors
  • Advanced Chemical Sensor Technologies

Birincil konu Analytical Chemistry and Sensors

Yazarlar

  1. ÖMER FARUK GÖKTAŞ
  2. EKİN DEMİRAY
  3. ALİ DEĞİRMENCİ ANKARA YILDIRIM BEYAZIT ÜNİVERSİTESİ
  4. İLYAS ÇANKAYA ANKARA YILDIRIM BEYAZIT ÜNİVERSİTESİ