Makale detayı · 2022 · article
Clinical Performance of Direct Posterior Composite Restorations in Patients with Amelogenesis Imperfecta
Veri kaynağı ayrımı
- YÖKSİSYÖKSİS makale kaydı
- YÖKSİS dergi adıOperative Dentistry
- Katalog eşleşmesi (ISSN)Operative Dentistry
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
The objective of this study was to analyze and assess the clinical performance of direct composite restorations using a nanohybrid and a nanofill composite material for posterior teeth in patients with amelogenesis imperfecta (AI). This study involved 15 patients between the ages of 14 and 30 years suffering from amelogenesis imperfecta (AI). During the study, the patients received direct composite restorations using either the Clearfil Majesty ES-2 (Kuraray Medical Inc, Tokyo, Japan) and Clearfil Universal Bond (Kuraray) or Filtek Ultimate Universal Restorative (3M ESPE, St Paul, MN, USA) and Single Bond Universal Adhesive (3M ESPE). The evaluations of the restorations were conducted per the modified USPHS criteria at the time of baseline as well as during the first-, second-, third-, and fourth-year follow-up sessions. After four years, it was observed that the cumulative success rate of direct posterior restorations was 98.1% for Clearfil Majesty ES-2 and 92.2% for Filtek Ultimate. During the study one Clearfil Majesty ES-2 restoration and four Filtek Ultimate restorations failed. There was a significant difference between Clearfil Majesty ES-2 and Filtek Ultimate in the color match in posterior restorations after three and four years. The causes of failure included marginal discoloration and caries, as well as fracture of the restoration. Hence, it can be stated that the use of nanohybrid or nanofill composites in posterior direct restorations in patients with AI looks promising. The failure rate of Clearfil Majesty ES-2 was found to be lower than that of Filtek Ultimate restorations. Clinically, the rate of optimum restorations conducted for partial discoloration, marginal adaptation, color match, and surface texture were observed to be higher when Clearfil Majesty ES-2 was used. However, additional studies are needed to assess the clinical performance of direct posterior composite materials in patients with AI.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
3atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2025 Evaluating the Clinical Performance of Highly Filled Injectable Composite and Condensable Universal Composite Restorations: A One-Year Randomized Clinical TrialAtıf 0 · OpenAlex
- 2025 Evaluating the Clinical Performance of Highly Filled Injectable Composite and Condensable Universal Composite Restorations: A One-Year Randomized Clinical TrialAtıf 0 · OpenAlex