Is it Possible to Implant HeartMate 3 Less Invasively? New Pump, New Approach

ISSN0160-564X
YÖKSİS OpenAlex
Yıl2018
Atıf30OpenAlex
Atıf24Semantic Scholar · 2 etkili
Yüzdelik%84,5
FWCI1,81,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q2

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıARTIFICIAL ORGANS
  • Katalog eşleşmesi (ISSN)Artificial Organs
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

HeartMate 3 (HM3) left ventricular assist device (LVAD) is a compact, intrapericardial, centrifugal flow pump with a fully magnetically levitated rotor and a wide range of operation (2-10 L/min) to accommodate a broad range of clinical needs. We analyzed our experience with Heartware VAD (HVAD) and HM3 implantation through minimally invasive left thoracotomy (MILT) and upper minimal J sternotomy. Between March 2015 and October 2016, 31 patients who underwent LVAD implantation through MILT were included in this study. Twenty-three patients had HVAD (Group A) implantation, whereas 8 patients had HM3 (Group B). To compare outcomes of these pumps, measures were; mortality, cardiopulmonary bypass (CPB) time, duration of mechanical ventilatory support, blood loss and transfusion, intensive care unit (ICU) stay, right ventricular failure (RVF) and requirement of support with temporary devices, stroke, pump thrombosis, gastrointestinal bleeding and driveline infection rates. Interagency Registry for Mechanically Assisted Circulatory Support profiles, Pennsylvania and Michigan Risk Scores, right ventricular stroke work index and central venous pressure/pulmonary capillary wedge pressure ratio did not differ between these two groups. There was no difference in the length of ICU stay (P = 0.056), post-operative blood product administration (P = 0.701), total time on mechanical ventilation (P = 0.386), RVF (P = 1) or duration of CPB (P = 0.836). In-hospital cerebrovascular event rate was 13% in Group A and 0% in Group B, respectively. The HM3 assist system can be successfully implanted with minimally invasive techniques. This technique has proved to be safe and reproducible, with good clinical outcomes. Further, large collaborative studies are needed to identify the advantages of this approach.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

30atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 8 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2021 A Stepwise Approach to Left Ventricular Assist Device Pump ThrombosisAtıf 6 · OpenAlex
  2. 2021 A Stepwise Approach to Left Ventricular Assist Device Pump ThrombosisAtıf 6 · OpenAlex
  3. 2023 Off-pump implantation of left ventricular assist device via minimally invasive left thoracotomy: Our single-center experienceAtıf 3 · OpenAlex
  4. 2021 Midterm Results of Minimally Invasive Left Thoracotomy Fully Magnetically Levitated Left Ventricular Assist Device ImplantationAtıf 3 · OpenAlex
  5. 2021 Midterm Results of Minimally Invasive Left Thoracotomy Fully Magnetically Levitated Left Ventricular Assist Device ImplantationAtıf 3 · OpenAlex
  6. 2023 Adaptation of adult right ventricular scoring systems to pediatric patients undergoing continuous LVAD implantation: Feasible or not?Atıf 2 · OpenAlex
  7. 2021 Does minimally invasive approach reduce risk of infection after ventricular assist device implantation?Atıf 2 · OpenAlex
  8. 2021 Does minimally invasive approach reduce risk of infection after ventricular assist device implantation?Atıf 2 · OpenAlex

Yazarlar

10
  1. SİNAN SABİT KOCABEYOĞLU 1
  2. ÜMİT KERVAN 2
  3. DOĞAN EMRE SERT 3
  4. ERTEKİN UTKU ÜNAL UFUK ÜNİVERSİTESİ 4
  5. BURCU DEMİRKAN SAĞLIK BİLİMLERİ ÜNİVERSİTESİ 5
  6. Yeşim Guray 6
  7. EMRE AYGÜN 7
  8. Osman Fehmi Beyazal 8
  9. MEHMET KARAHAN 9
  10. MUSTAFA PAÇ 10