İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2020 · article

Optimization with levosimendan improves outcomes after left ventricular assist device implantation

YÖKSİS OpenAlex Açık erişim · bronze
Yıl2020
Atıf15OpenAlex
Yüzdelik%62,3
FWCI0,61,00 = dünya ortalaması
Scopus (SJR)Q1
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıEUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
  • Katalog eşleşmesi (ISSN)European Journal of Cardio-thoracic Surgery
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

OBJECTIVES: The aim of this study was to examine the haemodynamic effects of preoperative levosimendan infusion in patients who underwent left ventricular assist device implantation and evaluate the prognoses. METHODS: Between May 2013 and October 2018, 85 adult patients who underwent left ventricular assist device implantation were included; 44 and 41 patients suffered from dilated cardiomyopathy and ischaemic cardiomyopathy, respectively. Patients were divided into 2 groups: group A (58 patients) included those who received levosimendan infusion in addition to other inotropes and group B (27 patients) included those who received inotropic agents other than levosimendan. Levosimendan infusion was started at a dose of 0.1 µg⋅kg-1⋅min-1 for a maximum of 48 h without a bolus. The primary outcome was early right ventricular failure (RVF). The secondary outcomes were in-hospital mortality, need for right ventricular assist device, late RVF and recovery of end-organ functions. The safety end points of levosimendan included hypotension, atrial fibrillation, ventricular tachycardia or fibrillation and resuscitated cardiac arrest. RESULTS: Patient characteristics were similar in both groups. No significant differences between groups were observed in the rates of early mortality, RVF, need for right ventricular assist device, cardiopulmonary bypass time and intensive care unit stay. Survival rates at 30 days, 1 year and 3 years and freedom from late RVF were similar between the groups. Administration of levosimendan was safe, generally well-tolerated and not interrupted because of side effects. CONCLUSIONS: Levosimendan therapy was well-tolerated in patients who received permanent left ventricular assist devices. Combined preoperative therapy with inotropes and levosimendan significantly improves end-organ functions.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

15atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2026 Optimization of levosimendan before left ventricular assist device implantation in pediatric patientsAtıf 0 · OpenAlex
  2. 2026 Optimization of levosimendan before left ventricular assist device implantation in pediatric patientsAtıf 0 · OpenAlex

Yazarlar

10
  1. SİNAN SABİT KOCABEYOĞLU 1
  2. ÜMİT KERVAN 2
  3. DOĞAN EMRE SERT 3
  4. MEHMET KARAHAN 4
  5. EMRE AYGÜN 5
  6. Osman Beyazal 6
  7. ERTEKİN UTKU ÜNAL UFUK ÜNİVERSİTESİ 7
  8. YEŞİM AKIN 8
  9. BURCU DEMİRKAN SAĞLIK BİLİMLERİ ÜNİVERSİTESİ 9
  10. MUSTAFA PAÇ 10