İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2024

Quantitative analysis of deep learning-based denoising model efficacy on optical coherence tomography images with different noise levels

YÖKSİS OpenAlex Açık erişim · hybrid SJR Q2 JCR Q3 Atıf 9 Yüzdelik 64.3% FWCI 0.72
Yıl
2024
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • YÖKSİS dergi adı Photodiagnosis and Photodynamic Therapy
  • Katalog eşleşmesi (ISSN) Photodiagnosis and Photodynamic Therapy
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex · İngilizce

BACKGROUND: To quantitatively evaluate the effectiveness of the Noise2Noise (N2N) model, a deep learning (DL)-based noise reduction algorithm, on enhanced depth imaging-optical coherence tomography (EDI-OCT) images with different noise levels. METHODS: The study included 30 subfoveal EDI-OCT images averaged with 100 frames from 30 healthy participants. Artificial Gaussian noise at 25.00, 50.00, and 75.00 standard deviations were added to the averaged (original) images, and the images were grouped as 25N, 50N, and 75N. Afterward, noise-added images were denoised with the N2N model and grouped as 25dN, 50dN, and 75dN, according to previous noise levels. The choroidal vascularity index (CVI) and deep choroidal contrast-to-noise ratio (CNR) were calculated for all images, and noise-added and denoised images were compared with the original images. The structural similarity of the noise-added and denoised images to the original images was assessed by the Multi-Scale Structural Similarity Index (MS-SSI). RESULTS: The CVI and CNR parameters of the original images (68.08 ± 2.47 %, and 9.71 ± 2.80) did not differ from the only 25dN images (67.97 ± 2.34 % and 8.50 ± 2.43) (p:1.000, and p:0.062, respectively). Noise reduction improved the MS-SSI at each noise level (p < 0.001). However, the highest MS-SSI was achieved in 25dN images. CONCLUSIONS: The DL-based N2N denoising model can be used effectively for images with low noise levels, but at increasing noise levels, this model may be insufficient to provide both the original structural features of the choroid and structural similarity to the original image.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

9 atıf

OpenAlex cited_by_count (önbellek / veritabanı)

Yazarlar

  1. FURKAN KIRIK BEZM-İ ÂLEM VAKIF ÜNİVERSİTESİ
  2. KAMİLE MELİS ERTÜRK
  3. FARID ISKANDAROV
  4. MEHMET HAKAN ÖZDEMİR BEZM-İ ÂLEM VAKIF ÜNİVERSİTESİ