Energy and Exergy Analysis of a Subcritical Cascade Refrigeration System With Internal Heat Exchangers Using Environmentally Friendly Refrigerants

YÖKSİS OpenAlex
Yıl2021
Atıf25OpenAlex
Atıf15Semantic Scholar · 2 etkili
Yüzdelik%78,8
FWCI1,331,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of Energy Resources Technology
  • Katalog eşleşmesi (ISSN)Journal of Energy Resources Technology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Abstract This study focuses on a thermodynamic performance analysis of a subcritical cascade refrigeration system (CRS) with internal heat exchangers (IHXs) using R41/R601, R41/R602A, and R41/cyclopentane as refrigerant pairs. The effect of evaporator temperature (Tev), condenser temperature (Tcond), and temperature difference in the cascade heat exchanger (ΔTCHX) on examined performance parameters are investigated. Each performance parameter is scrutinized by an optimum low-temperature circuit (LTC) condenser temperature. The operating parameters have some implications on the overall thermodynamic performance of the system. A change of 10 °C in the Tev and Tcond affects the performance of the system by approximately +26% and −8%, respectively. Moreover, a variation of 1 °C in the ΔTCHX reduces the performance of the system by about 2%. The effect of IHXs on the system has some interesting results. The coefficient of performance (COP) and exergy efficiency values of the system using R41/cyclopentane tend to constantly decrease by nearly 4.05%. Although not as much as R41/cyclopentane, there is also a slight drop in the performance of other refrigerant pairs. The discharge temperature in LTC and high-temperature circuit (HTC) compressors exceeds 120 °C for low-temperature refrigeration requirements, which is highly undesirable. Furthermore, the top priority components for the system improvement are HTC condenser, HTC compressor, and CHX. The refrigerant pairs with the thermodynamic performance from best to worst are R41/R601, R41/cyclopentane, and R41/R602A, respectively. Finally, the COP and exergy efficiency values of the modeled system are 10.40% higher and 3.06% lower, respectively, compared with current models in the literature.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

25atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 5 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2025 Experimental investigation of different cooling system configurations for a cold storage at ultra-low temperatureAtıf 3 · OpenAlex
  2. 2025 Experimental investigation of different cooling system configurations for a cold storage at ultra-low temperatureAtıf 3 · OpenAlex
  3. 2025 Experimental investigation of different cooling system configurations for a cold storage at ultra-low temperatureAtıf 2 · OpenAlex
  4. 2026 Comprehensive energy, exergy, economic, and environmental (4E) analyses and optimization of nanoparticles-doped cascade refrigeration system using low-GWP refrigerantsAtıf 0 · OpenAlex
  5. 2026 Comprehensive Energy, Exergy, Economical and Environmental (4E) Optimization of a Proposed Cascade Heat Pump System Using R152a/CyclopentaneAtıf 0 · OpenAlex

Yazarlar

2
  1. CENKER AKTEMUR SİVAS BİLİM VE TEKNOLOJİ ÜNİVERSİTESİ 1
  2. İLHAN TEKİN ÖZTÜRK 2