Makale detayı · 2018 · article
The Role of Ocular Response Analyzer in Differentiation of Forme Fruste Keratoconus from Corneal Astigmatism
Veri kaynağı ayrımı
- YÖKSİSYÖKSİS makale kaydı
- YÖKSİS dergi adıEye and Contact Lens-Science and Clinical Practice
- Katalog eşleşmesi (ISSN)Eye and Contact Lens
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
PURPOSE: To determine the diagnostic accuracy of corneal biomechanical factors in differentiating patients with forme fruste keratoconus (FFKC) from astigmatic and normal cases. METHODS: A total of 50 eyes with FFKC, 50 with astigmatism and 50 normal eyes, were included in this study. All patients had a detailed ophthalmologic examination including slit-lamp evaluation, Goldmann tonometry, indirect fundoscopy, topography by Scheimpflug imaging biomicroscopic anterior and posterior segment examination, and corneal biomechanical and intraocular pressure evaluation with ocular response analyzer (ORA). RESULTS: All topographic findings were statistically significant among the three groups (P>0.05). Although there was no statistically significant difference in the corneal-compensated intraocular pressure (IOPcc) among the three groups, the Goldmann-correlated intraocular pressure (IOPg), corneal hysteresis (CH), and corneal resistance factor (CRF) were statistically significantly lower in the FFKC group, compared with the other groups (P<0.001). There were no statistically significant difference in the IOPg, CH, and CRF between astigmatism and control groups (P=0.99, 0.79, and 0.86, respectively). The area under the receiver operating characteristic (AUROC) curve was greater than 0.85 for IOPg (0.80), CH (0.85), and CRF (0.90) for discriminating between FFKC and controls; whereas the AUROC was greater than 0.85 for IOPg (0.80), CH (0.79), and CRF (0.85) for discriminating between FFKC and astigmatism groups. CONCLUSION: Based on our study results, in differentiation of patients with FFKC from normal control cases or astigmatic patients, corneal biomechanical parameters play a role particularly in patients with suspicious results. We suggest using ORA in combination with corneal topography for better and more accurate diagnosis of FFKC.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
19atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 5 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2021 Biomechanical properties of the cornea following intravitreal ranibizumab injectionAtıf 2 · OpenAlex
- 2021 Biomechanical properties of the cornea following intravitreal ranibizumab injectionAtıf 2 · OpenAlex
- 2021 Biomechanical properties of the cornea following intravitreal ranibizumab injectionAtıf 2 · OpenAlex
- 2020 Biomechanical properties of the cornea following intravitreal ranibizumab injectionAtıf 2 · OpenAlex
- 2021 Effects of Hydrogel Contact Lens on Corneal Biomechanics and Intraocular PressureAtıf 0 · OpenAlex