Makale detayı · 2024
Investigation of the efficiency of different reprocessing methods on disposable laryngeal masks contaminated with HBV DNA
GMS Hygiene and Infection Control
- Yıl
- 2024
- ISSN
2196-5226- Tür
- article
Veri kaynağı ayrımı
- YÖKSİS YÖKSİS makale kaydı
- OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)
Özet
İngilizce (OpenAlex)
Background: The use of laryngeal masks (LM) has increased widely today, both in anesthesia and in emergency cases. LM are available as reusable and disposable. Although reuse of disposable LM is not recommended, they are reused again after decontamination with different methods in anesthesia units in some countries. The reprocessing of single-use LM was therefore investigated. The hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) are pathogens that can pass into saliva. It is known that the HBV is more resistant to decontamination methods as compared to HCV and HIV. Objectives: In this study, it was aimed to investigate the effectiveness of different decontamination methods on disposable and reusable LM and to evaluate the reusability of disposable LM after they were treated with simulated saliva samples containing HBV DNA. Study design and setting: The observational study was carried out in Medical Microbiology Department of Erciyes University Medicine Faculty between March 2016 and Mach 2018. Method: 3000) +5 minutes steam sterilization at 134°C was implemented only to reusable LM. At least three LM were used for each group. Control samples were also used. After the decontamination procedures, the LM were kept in phosphate buffer (PBS) solution for 1 hour at 37°C with shaking. The presence of HBV DNA was investigated by the real-time PCR by taking samples from PBS. The polyethylene glycol procedure was used for saliva and nucleic acid isolation. After the decontamination procedures, the functioning control of the LM was controlled. Results: 3000 thermal disinfection alone and disinfection with peracetic acid.While no deformation was observed in reusable LM after reprocessing, deformation was observed in disposable LM. Conclusion: Reuse with high-level disinfection, which is frequently applied to disposable LM, is an incorrect and dangerous practice, therefore disposable LM should not be reused. Reusable LM can be reused after being reprocessing with thermal disinfection + steam or thermal disinfection + hydrogen peroxide low temperature sterilization after effective cleaning.
Konular
- Medical Device Sterilization and Disinfection
- Airway Management and Intubation Techniques
- Infection Control in Healthcare
Birincil konu Medical Device Sterilization and Disinfection