İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2022 · article

Evaluation of PV Panel Power Loss Using Gabor Filter Bank

Dergi International Information and Engineering Technology Association (Traitement du Signal) ISSN kaydı başka bir dergiye işaret ediyor; ad YÖKSİS kaydından.
ISSN0765-0019
YÖKSİS OpenAlex Açık erişim · bronze
Yıl2022
Atıf3OpenAlex
Yüzdelik%32,4
FWCI0,11,00 = dünya ortalaması
Scopus (SJR)Q3
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıInternational Information and Engineering Technology Association (Traitement du Signal)
  • Katalog eşleşmesi (ISSN)Traitement du Signal (discontinued)
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Photovoltaic panels are subject to thermomechanical stresses during their production and subsequent life stages. These conditions give rise to cracks and other defects in panels that can affect power output. Cell cracking is one of the most important causes of power loss in photovoltaic panels. Therefore, photovoltaic panels and cells need to be monitored to achieve the maximum output during production and further downstream. Electroluminescent imaging is a powerful and established technique consisting of many electrically connected solar cells arranged on a grid, and it is employed in order for assessing the quality of photovoltaic panels. In this study, the detection of photovoltaic panel defects in electroluminescent images was examined through image processing methods. PV panels can consist of different numbers of cells. Performance evaluation is made on a cell-based and whole module basis. In PV panel production, unlike EL images taken in standard environments in the factory environment, EL images taken under field conditions require preprocessing before actually being processed. Features were extracted from the preprocessed EL images by exploiting Gabor filter. The obtained features were evaluated as cell-based and the stability of the cells was determined. The performance of the panel was calculated according to the power loss of the cells of the panel. When the calculated performance values were compared with the power values obtained by I-V measurement, the highest error was found to be 0.059, the lowest error was 0.004, and the average error was 0.0213. As a result, the highest success rate was 99.99%.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

3atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 1 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2024 Simulation and forecasting of power by energy harvesting method in photovoltaic panels using artificial neural networkAtıf 12 · OpenAlex

Yazarlar

1
  1. KERİM KARADAĞ HARRAN ÜNİVERSİTESİ 1