İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2025 · article

Predictive mathematical modeling of biomechanical behavior in all-on-4 implants design: effects of distal implant and occlusal load angulation using RSM based on FEA

YÖKSİS OpenAlex Açık erişim · gold Üst %10
Yıl2025
Atıf6OpenAlex
Yüzdelik%96,0
FWCI5,41,00 = dünya ortalaması
Scopus (SJR)Q1
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıFrontiers in Bioengineering and Biotechnology
  • Katalog eşleşmesi (ISSN)Frontiers in Bioengineering and Biotechnology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

This study presents a predictive biomechanical modeling approach for optimizing distal implant placement in the All-on-4 treatment concept, with a focus on implant angulation and occlusal load direction. Finite Element Analysis (FEA) was integrated with Response Surface Methodology (RSM) to develop 15 simulation models based on a Central Composite Design, incorporating distal implant angulations of 15°, 30°, and 45°, and occlusal load directions in both sagittal and frontal planes (45°, 67.5°, and 90°). The maximum von Mises stress in cortical bone was selected as the response variable. Regression analysis revealed that the frontal load angle had the most significant effect on stress distribution, followed by implant angulation. The resulting second-order predictive model demonstrated a strong statistical fit (R 2 = 93.39%, adjusted R 2 = 81.49%). The lowest cortical stress (95.75 MPa) occurred at 15° implant angulation with 45° occlusal loading in both planes, whereas the highest stress (265.72 MPa) was recorded at 45° angulation with 90° frontal loading. Although reducing implant tilt generally decreases peri-implant stress, no universally optimal angle can be defined due to variability in biomechanical responses under different occlusal loading conditions. Clinically, optimizing cusp inclination and load direction in conjunction with implant positioning may enhance the biomechanical performance and long-term success of full-arch implant-supported prostheses.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

6atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 1 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2026 Influence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysisAtıf 0 · OpenAlex

Yazarlar

3
  1. FAHRİ MURAT ERZURUM TEKNİK ÜNİVERSİTESİ 1
  2. SEMA NUR SEVİNÇ GÜL 2
  3. ABDULLAH TAHİR ŞENSOY SAMSUN ÜNİVERSİTESİ 3