İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2010 · article

Measurement of the muon stopping power in lead tungstate

ISSN1748-0221
YÖKSİS OpenAlex Açık erişim · bronze Üst %1
Yıl2010
Atıf43OpenAlex
Yüzdelik%99,8
FWCI22,421,00 = dünya ortalaması
Scopus (SJR)Q1
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJOURNAL OF INSTRUMENTATION
  • Katalog eşleşmesi (ISSN)Journal of Instrumentation
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO 4 ) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/ c to 1 TeV/ c . The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/ c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO 4 is measured to be 160 +5 −6 ±8 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

43atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 37 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2013 Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at root s=7 TeVAtıf 204 · OpenAlex
  2. 2013 Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at root s=7 TeVAtıf 197 · OpenAlex
  3. 2013 Energy Calibration and Resolution of the CMS Electromagnetic Calorimeter in pp Collisions at s 7 TeVAtıf 197 · OpenAlex
  4. 2013 Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s= 7 TeVAtıf 197 · OpenAlex
  5. 2013 Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s= 7 TeVAtıf 197 · OpenAlex
  6. 2010 Performance and operation of the CMS electromagnetic calorimeterAtıf 97 · OpenAlex
  7. 2010 Performance and operation of the CMS electromagnetic calorimeterAtıf 94 · OpenAlex
  8. 2010 Alignment of the CMS silicon tracker during commissioning with cosmic raysAtıf 94 · OpenAlex
  9. 2010 Performance and operation of the CMS electromagnetic calorimeterAtıf 93 · OpenAlex
  10. 2010 Performance and operation of the CMS electromagnetic calorimeterAtıf 93 · OpenAlex

Yazarlar

2
  1. CMS Collaboration 1
  2. AYŞE POLATÖZ ÇUKUROVA ÜNİVERSİTESİ 2